Cleaning  the  weighing  pan  while  still  installed  may  cause 
damage of the measuring system. 

 
 

3.1. Cleaning ABS Components 

 

To  clean  dry  surfaces  and  avoid  smudging,  use  clean  non-colouring  cloths 
made  of  cellulose  or  cotton.  You  can  use  a  solution  of  water  and  detergent 
(soap, dishwashing detergent, glass cleaner). Gently rub the dirty surface and 
let it dry. Repeat the cleaning process if necessary. 

 

In the case of hard to remove contamination, e.g. residues of adhesive, rubber, 
resin,  polyurethane  foam  etc.,  you  can  use  special  cleaning  agents  based  on  
a mixture of aliphatic hydrocarbons that do  not dissolve plastics. Before using 
the  cleanser,  for  all  surfaces  we  recommend  carrying  out  tests.  Do  not  use 
cleansers containing abrasive substances. 

 
 

3.2. Cleaning Stainless Steel Components 

 

Avoid  using  cleansers  containing  any  corrosive  chemicals,  e.g.  bleach  
(with  chlorine).  Do  not  use  cleansers  containing  abrasive  substances.  
Always  remove  the  dirt  using  microfiber  cloth  to  avoid  damage  of  protective 
coating. In case of a daily maintenance: 

1.  Remove the dirt using cloth dipped in warm water. 
2.  For best results, add a little bit of dishwashing detergent. 

 
 

4. SERVICE AND REPAIR  

 

 

In case of any sign of damage, it is necessary to disconnect 
the  device  form  the  mains  immediately.  The  damaged 
component  must  be  replaced  or  repaired  by  RADWAG 
service directly. 

 

In case of any problems with correct operation of the scale, contact the closest 
manufacturer's service point. 

 

In case of defects, deliver the faulty product to the manufacturer's service point. 
If  the  product  cannot  be  delivered  to  the  manufacturer's  service  point,  call  
the service and report the defect. Repair scope and method will be set up. 

Summary of Contents for WPY

Page 1: ......

Page 2: ...2 NOVEMBER 2020...

Page 3: ...K 6kg 2g 300x300mm WPY 6 F1 R 6kg 2g 300x300mm WPY 15 D2 15kg 5g 195x195mm WPY 15 F1 15kg 5g 300x300mm WPY 15 F1 K 15kg 5g 300x300mm WPY 15 F1 R 15kg 5g 300x300mm WPY 15 C2 15kg 5g 400x500mm WPY 15 C2...

Page 4: ...2 K 150kg 50g 400x500mm WPY 150 C2 R 150kg 50g 400x500mm WPY 150 C3 150kg 50g 500x700mm WPY 150 C3 K 150kg 50g 500x700mm WPY 300 C2 300kg 100g 400x500mm WPY 300 C2 K 300kg 100g 400x500mm WPY 300 C2 R...

Page 5: ...r and UV radiation substances causing chemical reactions The device must not be operated in hazardous areas endangered with explosion of gases and in dusty environments In case of damage immediately u...

Page 6: ...4 1 Technical Specifications 12 6 4 2 I O Schematic Diagrams 13 6 5 Operation Panel 13 7 INSTALLATION 14 7 1 UNPACKING AND INSTALLATION 14 7 1 1 WPY D2 Series 14 7 1 2 WPY F1 WPY C2 WPY C3 Series 14...

Page 7: ...rer and user representatives C RADWAG does not bear any responsibility for damage or losses resulting from unauthorized or inadequate performing of production or service processes D The warranty does...

Page 8: ...2 Cleaning Stainless Steel Components Avoid using cleansers containing any corrosive chemicals e g bleach with chlorine Do not use cleansers containing abrasive substances Always remove the dirt using...

Page 9: ...issioned must be decommissioned in accordance with valid legal regulations 6 MECHANICAL DESIGN WPY scale is a 1 load cell device intended to carry out fast and precise mass measurement of up to 300 kg...

Page 10: ...10 6 1 Dimensions Dimensions of WPY D2 scale Dimensions of WPY F1 R scale Dimensions of WPY F1 K scale Dimensions of WPY C2 R scale...

Page 11: ...s of WPY C3 K scale 6 2 Connectors 1 Ethernet RJ45 connector 2 RS232 COM1 connector 3 USB connector 1 power supply socket 2 I O RS232 COM2 connector 6 3 RS232 Connector RS232 DB9 M connector male fron...

Page 12: ...OUT RS232 DSUB15 F connector female front Pin1 GNDWE Pin2 OUT1 Pin3 OUT2 Pin4 COMM Pin6 IN4 Pin7 IN3 Pin11 IN2 Pin12 IN1 Pin14 OUT4 Pin15 OUT3 6 4 1 Technical Specifications Output parameters Output q...

Page 13: ...uts 4 outputs 6 5 Operation Panel Keys Press to switch the scale ON OFF Press to zero the scale Press to tare the scale Press to send the weighing result to a printer or a computer Press to enter the...

Page 14: ...a flat and even surface Keep it far away from any sources of heat C Install the weighing pan and the indicator holder in accordance with the figure below 7 1 2 WPY F1 WPY C2 WPY C3 Series Take the de...

Page 15: ...ly to the mains Connect the power supply plug to the socket located on the scale s side An ON LOAD diode on indicator housing is turned on Press key it is to be found at the top of the operation panel...

Page 16: ...name and symbol Log in entry Symbol informing that communication with a PC is on Symbol informing that Wi Fi connection is on Symbol informing that communication with E2R SYSTEM is on Device name Date...

Page 17: ...tively 8 4 Function Buttons On screen function buttons are to be found underneath the workspace You can define on screen function buttons individually for each working mode 9 OPERATING THE MENU 9 1 Op...

Page 18: ...to save the template to lb file the button becomes active upon USB flash drive connection Press to select printout template variables out of the list Press to go back Press to go to the home screen di...

Page 19: ...fied by EN 45501 standard point 3 6 2 In case of eccentric loading make sure that a mass of load placed close to one of the pan edges does not exceed of max capacity b mass of load placed in the pan c...

Page 20: ...20 11 DIAGRAMS OF CONNECTION CABLES Scale computer cable RS232 Scale printer cable ZEBRA Scale printer cable EPSON...

Page 21: ...21 I O cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends 12 ERROR MESSAGES...

Page 22: ...22...

Reviews: