Installing
a
Link
Chapter
4
For
any
type
of
IDU
‐
ODU
connection,
lightning
protection
units
(LPUs)
are
installed
in
pairs,
as
shown
in
the
next
figure:
Figure
4
‐
20:
Basic
use
of
lightning
protectors
To
install
a
LPU
on
a
pole
adjacent
to
an
ODU
(HBS
or
HSU):
1.
Mount
one
LPU
on
the
ODU
pole,
as
close
as
possible
to
the
ODU.
2.
Ground
the
LPU
to
the
pole
using
the
grounding
lug.
3.
Connect
the
0.5
meter
CAT
‐
5e
cable
to
the
IDU
port
of
the
ODU.
4.
Connect
the
other
end
of
the
cable
to
the
top
of
the
LPU.
5.
Tighten
the
top
cable
LPU
gland
cap.
6.
Connect
the
main
ODU
‐
IDU
cable
from
the
IDU
to
the
bottom
end
of
the
LPU.
7.
Tighten
the
bottom
cable
LPU
gland
cap.
8.
Run
the
main
ODU
‐
IDU
cable
towards
the
IDU
location.
9.
Insulate
both
LPU
connections.
See
the
next
section,
below
.
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......