RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
10
‐
6
Using
More
than
One
HSS
Unit
Chapter
10
4. To
add
a
further
HSS
unit:
Connect
the
next
available
SYNC
port
from
the
second
HSS
unit
in
descending
order
(SYNC
5
in
to
SYNC
1
of
the
third
HSS
unit.
5. ODUs
are
connected
to
the
third
HSS
unit
from
SYNC
2
as
shown
in
,
in
ascending
order
:
Figure
10
‐
8:
Cascading
three
HSS
units
6. If
further
ODUs
are
required,
observe
the
convention
that
additional
even
numbered
units
are
populated
in
descending
order
from
SYNC
9
and
odd
numbered
HSS
units
are
populated
in
ascending
order
from
SYNC
2.
Condition
2:
Total
HSS
Cable
Length
The
total
path
of
the
HSS
sync
pulse
must
not
exceed
300m.
This
applies
no
matter
how
many
HSS
units
are
used.
To
illustrate
the
method
for
calculating
the
sync
pulse
path
length
we
show
three
examples.
For
our
purpose,
let:
Lmn
denote
the
length
of
the
ODU
‐
HSS
unit
cable
at
SYNC
n
on
HSS
unit
m
Hm
be
the
length
of
the
cable
joining
HSS
unit
m
to
HSS
unit
m+1
One
HSS
unit
with
five
collocated
ODUs
Two
cascaded
HSS
units
as
shown
in
Note
If
an
ODU
is
disconnected
from
an
HSS
unit,
then
all
remaining
ODUs
must
be
moved
up
or
down
to
maintain
the
connectivity.
PathLength
L
11
2
L
12
2
L
13
+
2
L
14
L
15
+
+
+
=
PathLength
L
11
2
L
12
2
L
13
2
L
14
+
2
+
L
15
+
H
1
2
L
29
2
+
L
28
2
+
L
27
L
26
+
+
+
+
=
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......