RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
6
Private
MIB
Parameters
Chapter
C
Private
MIB
Parameters
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
1
of
32)
Name
OID
Type
A
cce
ss
Description
winlink1000OduAdmProductType
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
RO
ODU
configuration
description.
winlink1000OduAdmHwRev
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
RO
ODU
Hardware
Version.
winlink1000OduAdmSwRev
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
RO
ODU
Software
Version.
winlink1000OduAdmLinkName
1.3.6.1.4.1.4458.1000.1.1.4
DisplayString
RW Link
Name.
A
change
is
effective
immediately.
winlink1000OduAdmResetCmd
1.3.6.1.4.1.4458.1000.1.1.5
Integer
RW Reset
Command.
A
set
command
with
a
value
of
3
will
cause
a
device
reset.
HBS
only:
A
set
command
with
a
value
of
4
will
cause
a
device
reset
for
the
entire
sector.
The
read
value
is
always
0.
winlink1000OduAdmAddres
1.3.6.1.4.1.4458.1000.1.1.6
IPAddress
RW ODU
IP
address.
A
change
is
effective
after
reset.
The
parameter
is
kept
for
backward
compatibility.
Using
the
alternative
parameter:
winlink1000OduAdmIpParamsCnfg
is
recommended.
winlink1000OduAdmMask
1.3.6.1.4.1.4458.1000.1.1.7
IPAddress
RW ODU
Subnet
Mask.
A
change
is
effective
after
reset.
The
parameter
is
kept
for
backward
compatibility.
Using
the
alternative
parameter:
winlink1000OduAdmIpParamsCnfg
is
recommended.
winlink1000OduAdmGateway
1.3.6.1.4.1.4458.1000.1.1.8
IPAddress
RW ODU
default
gateway.
A
change
is
effective
after
reset.
The
parameter
is
kept
for
backward
compatibility.
Using
the
alternative
parameter:
winlink1000OduAdmIpParamsCnfg
is
recommended.
winlink1000OduAdmBroadcast
RW This
parameter
is
reserved
for
the
Manager
application
provided
with
the
product.
winlink1000OduAdmHostsTable
N/A Trap
destinations
table.
Each
trap
destination
is
defined
by
an
IP
address
and
a
UDP
port.
Up
to
10
addresses
can
be
configured.
winlink1000OduAdmHostsEntry
N/A Trap
destinations
table
entry.
INDEX
{
winlink1000OduAdmHostsIndex
}
winlink1000OduAdmHostsIndex
1.3.6.1.4.1.4458.1000.1.1.1
2.1.1
Integer
RO
Trap
destinations
table
index.
winlink1000OduAdmHostsIp
1.3.6.1.4.1.4458.1000.1.1.1
2.1.2
IPAddress
RW Trap
destination
IP
address.
A
change
is
effective
immediately.
winlink1000OduAdmHostsPort
1.3.6.1.4.1.4458.1000.1.1.1
2.1.3
Integer
RW UDP
port
of
the
trap
destination.
A
change
is
effective
immediately.
winlink1000OduAdmHostsSecurity
Model
1.3.6.1.4.1.4458.1000.1.1.1
2.1.4
Integer
RW Security
model
used
for
this
trap
generation.
winlink1000OduAdmHostsUserNam
e
1.3.6.1.4.1.4458.1000.1.1.1
2.1.5
DisplayString
RW User
name
used
to
generate
the
snmpv3
trap.
winlink1000OduAdmHostsPasswor
d
1.3.6.1.4.1.4458.1000.1.1.1
2.1.6
DisplayString
RW Password
used
to
generate
the
snmpv3
trap.
winlink1000OduBuzzerAdminState
1.3.6.1.4.1.4458.1000.1.1.1
3
Integer
RW This
parameter
controls
the
activation
of
the
buzzer
while
the
unit
is
in
install
mode.
A
change
is
effective
immediately.
The
valid
values
are:
disabled
(0)
enabledAuto
(1)
enabledConstantly(2)
advancedAuto
(3).
winlink1000OduProductId
1.3.6.1.4.1.4458.1000.1.1.1
4
DisplayString
RO
This
parameter
is
reserved
for
the
Manager
application
provided
with
the
product.
winlink1000OduReadCommunity
1.3.6.1.4.1.4458.1000.1.1.1
5
DisplayString
RW Read
Community
String.
This
parameter
always
returns
*****
when
retrieving
its
value.
It
is
used
by
the
Manager
application
to
change
the
Read
Community
String.
The
SNMP
agent
accepts
only
encrypted
values.
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......