RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
9
Private
MIB
Parameters
Chapter
C
winlink1000OduSrvQoSDiffservQGr
oupsSetStr
RW Frames
classification
according
to
Diffserv
IDs
string
for
set.
winlink1000OduSrvQoSMaxRTQueP
ercent
RO
Maximal
percent
for
RT
&
NRT
queues.
winlink1000OduSrvVlanSupport
RO
ODU
Ethernet
port
VLAN
support
and
configuration
availability
indication.
1
‐
ODU
VLAN
Functionality
Not
Supported
2
‐
ODU
VLAN
Functionality
Supported
3
‐
ODU
VLAN
Functionality
Supported
and
Available
winlink1000OduSrvVlanIngressMod
e
RW ODU
Ethernet
port
ingress
VLAN
mode.
winlink1000OduSrvVlanEgressMod
e
RW ODU
Ethernet
port
egress
VLAN
mode.
winlink1000OduSrvEgressTag
RW ODU
ethernet
port
egress
VLAN
tag.
Right
most
digit
is
Vlan
priority
(0
‐
7)
other
digits
compose
Vlan
Id
(2
‐
4094)
winlink1000OduSrvEgressProviderT
ag
RW ODU
ethernet
port
egress
Provider
VLAN
tag.
Right
most
digit
is
Vlan
priority
(0
‐
7)
other
digits
compose
Vlan
Id
(2
‐
4094)
winlink1000OduSrvVlanIngressAllo
wedVIDs
RW ODU
ethernet
port
VLAN
IDs
that
will
not
be
filtered
on
ingress.
w|w|w|w|w|w|w|w|
(
where
w
=
{0
‐
4094}
and
w
!=
1
)
winlink1000OduSrvVlanDisable
RW Disable
VLAN
functionality.
The
following
values
can
be
set:
3
‐
Disable
ODU
&
IDU
VLAN
Configurations.
winlink1000OduServiceVlanProvide
rListTPIDstr
1.3.6.1.4.1.4458.1000.1.2.6.
8
DisplayString
RO
Holds
the
possible
Provider
TPIDs.
winlink1000OduEthernetRemaining
Rate
1.3.6.1.4.1.4458.1000.1.3.1
Integer
RO
Current
Ethernet
bandwidth
in
bps.
winlink1000OduEthernetIfTable
N/A ODU
Ethernet
Interface
table.
winlink1000OduEthernetIfEntry
N/A ODU
Ethernet
Interface
table
entry.
INDEX
{
winlink1000OduEthernetIfIndex
}
winlink1000OduEthernetIfIndex
1.3.6.1.4.1.4458.1000.1.3.2.
1.1
Integer
RO
ODU
Ethernet
Interface
Index.
winlink1000OduEthernetIfAddress
1.3.6.1.4.1.4458.1000.1.3.2.
1.5
DisplayString
RO
ODU
MAC
address.
winlink1000OduEthernetIfAdminSt
atus
1.3.6.1.4.1.4458.1000.1.3.2.
1.6
Integer
RW Required
state
of
the
interface.
winlink1000OduEthernetIfOperStat
us
1.3.6.1.4.1.4458.1000.1.3.2.
1.7
Integer
RO
Current
operational
state
of
the
interface.
winlink1000OduEthernetIfFailActio
n
1.3.6.1.4.1.4458.1000.1.3.2.
1.8
Integer
RW Failure
action
of
the
interface.
winlink1000OduEthernetNumOfPor
ts
1.3.6.1.4.1.4458.1000.1.3.3
Integer
RO
Number
of
ODU
network
interfaces.
winlink1000OduEthernetGbeSuppo
rted
1.3.6.1.4.1.4458.1000.1.3.4
Integer
RO
Supported
Giga
bit
Ethernet
in
ODU.
winlink1000OduBridgeBasePortTabl
e
N/A ODU
Bridge
Ports
table.
winlink1000OduBridgeBasePortEntr
y
N/A ODU
Bridge
Ports
table
entry.
INDEX
{
winlink1000OduBridgeBasePortIndex
}
winlink1000OduBridgeBasePortInd
ex
RO
ODU
Bridge
Port
Number.
winlink1000OduBridgeBaseIfIndex
RO
IfIndex
corresponding
to
ODU
Bridge
port.
winlink1000OduBridgeTpMode
1.3.6.1.4.1.4458.1000.1.4.4.
101
Integer
RW ODU
bridge
mode.
A
change
is
effective
after
reset.
Valid
values:
hubMode
(0)
bridgeMode
(1).
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
4
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......