RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
10
Private
MIB
Parameters
Chapter
C
winlink1000OduBridgeTpPortTable
N/A ODU
Transparent
Bridge
Ports
table.
winlink1000OduBridgeTpPortEntry
N/A ODU
Transparent
Bridge
Ports
table
entry.
INDEX
{
winlink1000OduBridgeTpPortIndex
}
winlink1000OduBridgeTpPortIndex
RO
ODU
Transparent
Bridge
Port
Number.
winlink1000OduBridgeTpPortInFra
mes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.3
Counter
RO
Number
of
frames
received
by
this
port.
winlink1000OduBridgeTpPortOutFr
ames
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.4
Counter
RO
Number
of
frames
transmitted
by
this
port.
winlink1000OduBridgeTpPortInByte
s
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.101
Counter
RO
Number
of
bytes
received
by
this
port.
winlink1000OduBridgeTpPortOutBy
tes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.102
Counter
RO
Number
of
bytes
transmitted
by
this
port.
winlink1000OduBridgeConfigMode
1.3.6.1.4.1.4458.1000.1.4.4.
102
Integer
RO
ODU
bridge
configuration
mode
winlink1000OduAirFreq
1.3.6.1.4.1.4458.1000.1.5.1
Integer
RW Installation
Center
Frequency.
Valid
values
are
product
dependent.
A
change
is
effective
after
link
re
‐
synchronization.
winlink1000OduAirDesiredRate
1.3.6.1.4.1.4458.1000.1.5.2
Integer
RW Deprecated
parameter
actual
behavior
is
read
‐
only.
Required
Air
Rate.
For
Channel
Bandwidth
of
20
10
5
MHz
divide
the
value
by
1
2
4
respectively.
winlink1000OduAirSSID
1.3.6.1.4.1.4458.1000.1.5.3
DisplayString
RW Reserved
for
the
Manager
application
provided
with
the
product.
The
Sector
ID
in
Point
‐
To
‐
Multi
‐
Point
systems.
winlink1000OduAirTxPower
1.3.6.1.4.1.4458.1000.1.5.4
Integer
RW Required
Transmit
power
in
dBm
.
This
is
a
nominal
value
while
the
actual
transmit
power
includes
additional
attenuation.
The
min
and
max
values
are
product
specific.
A
change
is
effective
immediately.
winlink1000OduAirSesState
1.3.6.1.4.1.4458.1000.1.5.5
Integer
RO
Current
Link
State.
The
value
is
active
(3)
during
normal
operation.
winlink1000OduAirMstrSlv
1.3.6.1.4.1.4458.1000.1.5.6
Integer
RO
This
parameter
indicates
if
the
device
was
automatically
selected
into
the
radio
link
master
or
slave.
The
value
is
undefined
if
there
is
no
link.
The
value
is
relevant
only
for
point
to
point
systems.
winlink1000OduAirResync
1.3.6.1.4.1.4458.1000.1.5.8
Integer
RW Setting
this
parameter
to
1
will
cause
the
link
to
restart
the
synchronization
process.
winlink1000OduAirRxPower
1.3.6.1.4.1.4458.1000.1.5.9.
1
Integer
RO
Received
Signal
Strength
in
dBm.
Relevant
only
for
point
to
point
systems.
winlink1000OduAirTotalFrames
1.3.6.1.4.1.4458.1000.1.5.9.
2
Counter
RO
Total
number
of
radio
frames.
winlink1000OduAirBadFrames
1.3.6.1.4.1.4458.1000.1.5.9.
3
Counter
RO
Total
number
of
received
radio
frames
with
CRC
error.
The
value
is
relevant
only
for
point
to
point
systems
.
winlink1000OduAirCurrentRate
1.3.6.1.4.1.4458.1000.1.5.9.
4
Integer
RO
Deprecated
parameter.
Actual
rate
of
the
air
interface
in
Mbps.
For
Channel
Bandwidth
of
20
10
5
MHz
divide
the
value
by
1
2
4
respectively.
winlink1000OduAirCurrentRateIdx
1.3.6.1.4.1.4458.1000.1.5.9.
5
Integer
RO
Index
of
current
air
rate.
winlink1000OduAirTxPower36
1.3.6.1.4.1.4458.1000.1.5.1
0
Integer
RW Deprecated
parameter.
Actual
behavior
is
read
‐
only.
winlink1000OduAirTxPower48
1.3.6.1.4.1.4458.1000.1.5.1
1
Integer
RW Deprecated
parameter.
Actual
behavior
is
read
‐
only.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
5
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......