RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
21
Private
MIB
Parameters
Chapter
C
winlink1000OduPerfMonAirInterval
MinRSL
RO
Current
Min
Received
Level
Reference
per
interval.
winlink1000OduPerfMonAirInterval
MaxRSL
RO
Current
Max
Received
Level
Reference
per
interval.
winlink1000OduPerfMonAirInterval
RSLThresh1Exceed
RO
Number
of
seconds
Receive
Signal
Level
exceeded
the
RSL1
threshold
per
interval.
winlink1000OduPerfMonAirInterval
RSLThresh2Exceed
Number
of
seconds
Receive
Signal
Level
exceeded
the
RSL2
threshold
ACCESS
read
‐
only
per
interval.
winlink1000OduPerfMonAirInterval
MinTSL
RO
Current
Min
Transmit
Signal
Level
per
interval.
winlink1000OduPerfMonAirInterval
MaxTSL
RO
Current
Max
Transmit
Signal
Level
per
interval.
winlink1000OduPerfMonAirInterval
TSLThresh1Exceed
RO
Number
of
seconds
Transmit
Signal
Level
exceeded
the
TSL1
threshold
per
interval.
winlink1000OduPerfMonAirInterval
BBERThresh1Exceed
RO
Number
of
seconds
Background
Block
Error
Ratio
exceeded
the
BBER1
threshold
per
interval.
winlink1000OduPerfMonAirDayTabl
e
N/A This
table
defines/keeps
the
air
counters
of
the
last
month
(in
resolution
of
days).
winlink1000OduPerfMonAirDayEntr
y
N/A This
is
an
entry
in
the
Days
Table.
INDEX
{ifIndex
winlink1000OduPerfMonAirDayIdx
}
winlink1000OduPerfMonAirDayIdx
RO
This
table
is
indexed
per
Day
number.
Each
Day
is
of
15
minutes
and
the
oldest
is
96.
winlink1000OduPerfMonAirDayMin
RSL
RO
Current
Min
Received
Level
Reference
per
Day.
winlink1000OduPerfMonAirDayMa
xRSL
RO
Current
Max
Received
Level
Reference
per
Day.
winlink1000OduPerfMonAirDayRSL
Thresh1Exceed
RO
Number
of
seconds
Receive
Signal
Level
exceeded
the
RSL1
threshold
per
Day.
winlink1000OduPerfMonAirDayRSL
Thresh2Exceed
RO
Number
of
seconds
Receive
Signal
Level
exceeded
the
RSL2
threshold
per
Day.
winlink1000OduPerfMonAirDayMin
TSL
RO
Current
Min
Transmit
Signal
Level
per
Day.
winlink1000OduPerfMonAirDayMa
xTSL
RO
Current
Max
Transmit
Signal
Level
per
Day.
winlink1000OduPerfMonAirDayTSL
Thresh1Exceed
RO
Number
of
seconds
Transmit
Signal
Level
exceeded
the
TSL1
threshold
per
Day.
winlink1000OduPerfMonAirDayBBE
RThresh1Exceed
RO
Number
of
seconds
Background
Block
Error
Ratio
exceeded
the
BBER1
threshold
per
Day.
winlink1000OduPerfMonEthCurrTa
ble
N/A This
table
defines/keeps
the
ethernet
counters
of
the
current
15
min
interval.
winlink1000OduPerfMonEthCurrEn
try
N/A This
is
an
entry
in
the
Current
Interval
Table.
INDEX
{ifIndex
}
winlink1000OduPerfMonEthCurrRx
MBytes
1.3.6.1.4.1.4458.1000.1.6.7.
1.1
Gauge
RO
Current
RX
Mega
Bytes
starting
from
the
present
15
minutes
period.
winlink1000OduPerfMonEthCurrTx
MBytes
1.3.6.1.4.1.4458.1000.1.6.7.
1.2
Gauge
RO
Current
Transmit
Mega
Bytes
starting
from
the
present
15
minutes
period.
winlink1000OduPerfMonEthCurrEt
hCapacityThreshUnder
1.3.6.1.4.1.4458.1000.1.6.7.
1.3
Gauge
RO
The
number
of
times
throughput
was
below
threshold
in
the
present
15
minutes
period.
Relevant
for
point
to
point
systems.
winlink1000OduPerfMonEthCurrHi
ghTrafficThreshExceed
1.3.6.1.4.1.4458.1000.1.6.7.
1.4
Gauge
RO
The
number
of
times
actual
traffic
was
above
threshold
in
the
present
15
minutes
period.
winlink1000OduPerfMonEthCurrAc
tiveSeconds
1.3.6.1.4.1.4458.1000.1.6.7.
1.5
Gauge
RO
The
number
of
seconds
in
which
RPL
Ethernet
swervice
was
not
blocked
in
the
present
15
minutes
period.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
16
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......