RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
23
Private
MIB
Parameters
Chapter
C
winlink1000OduPerfMonTdmDayEn
try
N/A This
is
an
entry
in
the
Days
Table.
INDEX
{ifIndex
winlink1000OduPerfMonTdmDayIdx
}
winlink1000OduPerfMonTdmDayId
x
RO
This
table
is
indexed
per
Day
number.
Each
interval
is
of
15
minutes
and
the
oldest
is
96.
winlink1000OduPerfMonTdmDayAc
tiveSeconds
RO
Parameter
indicating
whether
the
TDM
service
was
active.
Under
TDM
backup
link
the
parameter
indicates
whether
the
backup
link
was
active.
winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
0
Integer
RW When
the
Transmit
power
exceeds
this
threshold
a
performance
monitoring
TSL1
counter
is
incremented.
winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
1
Integer
RW When
the
RX
power
exceeds
this
threshold
a
performance
monitoring
RSL1
counter
is
incremented.
winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.2
2
Integer
RW When
the
RX
power
exceeds
this
threshold
a
performance
monitoring
RSL2
counter
is
incremented.
winlink1000OduPerfMonBBERThres
h1
1.3.6.1.4.1.4458.1000.1.6.2
3
Integer
RW When
the
BBER
exceeds
this
threshold
a
performance
monitoring
BBER
counter
is
incremented.
The
units
are
1/10
of
a
percent.
winlink1000OduPerfMonEthCapacit
yThreshKbps
1.3.6.1.4.1.4458.1000.1.6.2
4
Integer
RW When
the
current
throughput
is
below
this
threshold
the
corresponding
counter
is
incremented
winlink1000OduPerfMonHighTraffic
ThreshKbps
1.3.6.1.4.1.4458.1000.1.6.2
5
Integer
RW When
the
current
traffic
is
above
this
threshold
then
corresponding
counter
is
incremented.
winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1.
1
Integer
RW If
'yes'
is
chosen
the
ifIndex
Unit
Severity
Time_T
and
Alarm
Id
from
the
winlink1000OduAgnCurrAlarmTable
will
be
bind
to
the
end
of
each
private
trap.
winlink1000OduAgnGenSetMode
1.3.6.1.4.1.4458.1000.1.7.1.
2
Integer
RW This
parameter
is
reserved
to
the
element
manager
provided
with
the
product.
winlink1000OduAgnGenLocalConne
ctionMode
RW Local
Connection
(Broadcast)
Configuration
Mode.
Options
are:
1
‐
SNMP
Read
‐
Write
2
‐
SNMP
Read
‐
Only.
winlink1000OduAgnNTPCfgTimeSer
verIP
1.3.6.1.4.1.4458.1000.1.7.2.
1
IPAddress
RW IP
address
of
the
server
from
which
the
current
time
is
loaded.
winlink1000OduAgnNTPCfgTimeOff
setFromUTC
1.3.6.1.4.1.4458.1000.1.7.2.
2
Integer
RW Offset
from
Coordinated
Universal
Time
(minutes).
Possible
values:
‐
1440..1440.
winlink1000OduAgnRealTimeAndD
ate
1.3.6.1.4.1.4458.1000.1.7.2.
3
OctetString
RW This
parameter
specifies
the
real
time
and
date
Format
'YYYY
‐
MM
‐
DD
HH:MM:SS'
(Hexadecimal).
A
date
‐
time
specification:
field
octets
contents
range
‐‐‐‐‐ ‐‐
‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐‐
1
1
‐
2
year
0..65536
2
3
month
1..12
3
4
day
1..31
4
5
hour
0..23
5
6
minutes
0..59
6
7
seconds
0..60
(use
60
for
leap
‐
second)
7
8
deci
‐
seconds
0..9
For
example
Tuesday
May
26
1992
at
1:30:15
PM
EDT
would
be
displayed
as:
07
c8
05
1a
0d
1e
0f
00
(
1992
‐
5
‐
26
13:30:15
)
winlink1000OduAgnCurrAlarmLastC
hange
1.3.6.1.4.1.4458.1000.1.7.3.
1
Integer
RO
This
counter
is
initialized
to
0
after
a
device
reset
and
is
incremented
upon
each
change
in
the
winlink1000OduAgnCurrAlarmTable
(either
an
addition
or
removal
of
an
entry).
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
18
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......