RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
28
Private
MIB
Parameters
Chapter
C
winlink1000IduTdmMasterClockAva
ilOptions
RO
Available
options
of
the
TDM
Master
Clock
Control
each
input
status
is
represented
by
a
bit.
When
the
option
is
available
the
bit
value
is
1.
When
the
option
is
unavailable
the
bit
value
is
0.
The
available
options
are:
bit
2
=
Automatic
bit
3
=
Trunk
#1
bit
4
=
Trunk
#2
bit
5
=
Trunk
#3
bit
6
=
Trunk
#4
When
no
options
are
available
the
returned
value
is:
1
winlink1000IduTdmMasterClockDes
ired
RW Required
TDM
Master
Clock.
A
change
is
effective
after
re
‐
activation
of
the
TDM
service.
winlink1000IduTdmMasterClockAct
ual
RO
Actual
Trunk
used
for
TDM
Master
Clock.
winlink1000IduTdmConfigTable
N/A IDU
TDM
Links
Configuration
table.
winlink1000IduTdmConfigEntry
N/A IDU
TDM
Links
Configuration
table
entry.
INDEX
{
winlink1000IduTdmConfigIndex
}
winlink1000IduTdmConfigIndex
RO
Table
index.
winlink1000IduTdmIfIndex
RO
Link
index
in
the
interface
table.
winlink1000IduTdmLineCoding
RW This
parameter
applies
to
T1
trunks
only.
The
parameter
controls
the
line
coding.
Setting
the
value
to
each
of
the
indices
applies
to
all.
A
change
is
effective
after
the
next
open
of
the
TDM
service.
winlink1000IduTdmLoopbackConfig
RW Loop
back
configuration
table.
Each
of
the
trunks
can
be
set
Normal
Line
loop
back
or
Reverse
line
loop
back.
A
change
is
effective
immediately.
winlink1000IduTdmLineStatus
RO
Line
status.
winlink1000IduTdmCurrentTable
N/A IDU
TDM
Links
Statistics
table.
winlink1000IduTdmCurrentEntry
N/A IDU
TDM
Links
Statistics
table
entry.
INDEX
{
winlink1000IduTdmCurrentIndex
}
winlink1000IduTdmCurrentIndex
RO
Table
index
(Same
as
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks
RO
Number
of
correct
blocks
transmitted
to
the
line.
winlink1000IduTdmCurrentDrops
RO
Number
of
error
blocks
transmitted
to
the
line.
winlink1000IduTdmCurrentTxClock
RW TDM
Transmit
Clock.
A
change
is
effective
after
re
‐
activation
of
the
TDM
service.
winlink1000IduTdmCurrentBlocksHi
gh
RO
High
part
of
the
64
bits
counter
Current
Blocks
winlink1000IduTdmRemoteQual
RO
Estimated
average
interval
between
error
second
events.
The
valid
values
are
1
‐
2^31
where
a
value
of
‐
1
is
used
to
indicate
an
undefined
state.
winlink1000IduTdmRemoteQualEva
l
RO
Estimated
average
interval
between
error
second
events
during
evaluation
process.
The
valid
values
are
1
‐
2^31
where
a
value
of
‐
1
is
used
to
indicate
an
undefined
state.
winlink1000IduTdmSrvEval
RW Evaluated
TDM
service
bit
mask.
Setting
this
parameter
to
value
that
is
bigger
than
the
activated
TDM
service
bit
mask
will
execute
the
evaluation
process
for
30
seconds.
Setting
this
parameter
to
0
will
stop
the
evaluation
process
immediately.
winlink1000IduTdmBackupAvailabl
eLinks
RO
Number
of
TDM
backup
trunks.
winlink1000IduTdmBackupTable
N/A IDU
TDM
Links
Statistics
table.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
23
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......