RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
29
Private
MIB
Parameters
Chapter
C
winlink1000IduTdmBackupEntry
N/A IDU
TDM
Links
Statistics
table
entry.
INDEX
{
winlink1000IduTdmBackupIndex
}
winlink1000IduTdmBackupIndex
RO
Table
index.
winlink1000IduTdmBackupMode
RW TDM
backup
mode:
Enable
or
Disable
where
the
main
link
is
the
air
link
or
the
external
link.
Changes
will
be
effective
immediatly.
winlink1000IduTdmBackupCurrentA
ctiveLink
RO
TDM
backup
current
active
link:
N/A
air
link
is
active
or
external
link
is
active.
winlink1000IduTdmJitterBufferSize
RW TDM
Jitter
Buffer
Size.
The
value
must
be
between
the
minimum
and
the
maximum
TDM
Jitter
Buffer
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferDefa
ultSize
RO
TDM
Jitter
Buffer
Default
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferMinS
ize
RO
TDM
Jitter
Buffer
Minimum
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferMax
Size
RO
TDM
Jitter
Buffer
Maximum
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferSizeE
val
RW TDM
Jitter
Buffer
Size
for
evaluation.
The
value
must
be
between
the
minimum
and
the
maximum
TDM
Jitter
Buffer
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmType
RW TDM
Type
(The
value
undefined
is
read
‐
only).
winlink1000IduTdmTypeEval
RW TDM
Type
for
evaluation.
winlink1000IduTdmLineStatusStr
RO
Line
status.
winlink1000IduTdmHotStandbySup
port
RO
Indicates
if
Hot
Standby
is
supported.
winlink1000IduTdmDesiredHotStan
dbyMode
RW Desired
Hot
Standby
Mode.
winlink1000IduTdmHotStandbyOpe
rationStatus
RO
The
Link
Actual
Status.
winlink1000IduTdmBackupLinkConf
iguration
RW The
current
configuration
of
the
backup
link.
winlink1000IduTdmLineInterfaceCo
nfiguration
RW TDM
Line
interface
configuration.
winlink1000IduTdmLineImpedance
Configuration
RW TDM
line
impedance
configuration
(standardT1
‐
100Ohm
nonStandardT1
‐
110Ohm)
Applicable
only
for
T1
TDM
type.
winlink1000HbsAirState
1.3.6.1.4.1.4458.1000.3.1.1
Integer
RO
Holds
the
state
of
the
HBS.
winlink1000HbsAirOpMode
1.3.6.1.4.1.4458.1000.3.1.2
Integer
RW Holds
the
operation
mode
of
the
HBS.
winlink1000HbsAirAvailTimeSlots
1.3.6.1.4.1.4458.1000.3.1.3
Integer
RO
This
parameter
holds
the
number
of
available
time
slots
(not
in
use)
in
the
air
interface.
winlink1000HbsAirSectorCbwSuppo
rtedStr
1.3.6.1.4.1.4458.1000.3.1.4
DisplayString
RO
Represents
the
channel
bandwidth
which
is
supported
by
the
HBS
and
all
connected
HSUs.
winlink1000HbsAirCompressedMon 1.3.6.1.4.1.4458.1000.3.1.5
OctetString
RO
Holds
HBS
monitor
data
in
compressed
format:
HBS
Traffic
Monitor
In
Bytes(4)
Out
Bytes(4)
In
Frames(4)
Out
Frames(4)
HBS
State
(1)
HBS
Freq
(4)
Number
of
Links
(2)
EC
Change
Counter
(4)
Current
Ratio
(2)
Total
Air
Frames
(4)
HBS
Rx
Rate
in
Kbps
(4)
HBS
Tx
Rate
in
Kbps
(4)
HBS
Rx
Rate
in
Fps
(4)
HBS
Tx
Rate
in
Fps
(4)
HBS
Set
Mode
(1).
winlink1000HbsAirConfChanges
1.3.6.1.4.1.4458.1000.3.1.6.
1
OctetString
RO
16
characters
that
represent
16
HSUs.
Each
time
a
configuration
is
been
changed
increment
the
relevant
character.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
24
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......