RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
38
MIB
Traps
Chapter
C
MIB
Traps
General
Each
ODU
can
be
configured
with
up
to
10
different
trap
destinations.
When
the
link
is
operational,
each
ODU
sends
traps
originating
from
both
Site
A
and
Site
B.
The
source
IP
address
of
the
trap
is
the
sending
ODU.
The
trap
originator
can
be
identified
by
the
trap
Community
string
or
by
the
trap
description
text.
Each
trap
contains
a
trap
description
and
additional
relevant
information
such
as
alarm
severity,
interface
index,
time
stamp
and
additional
parameters.
Trap
Parameters
Table
C
‐
3:
MIB
Traps
(Sheet
1
of
8)
Name
ID
Severity
Description
trunkStateChanged
1
normal
Indicates
a
change
in
the
state
of
one
of
the
TDM
trunks.
Raised
by
both
sides
of
the
link.
Contains
3
parameters:
1
‐
Description:
TDM
Interface
%n
‐
%x
2
‐
%n:
Is
the
trunk
number
3
‐
%x:
Is
the
alarm
type
and
can
be
one
of
the
following:
Normal
AIS
LOS
Loopback
linkUp
2
normal
Indicates
that
the
radio
link
is
up.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Radio
Link
‐
Sync
on
channel
%n
GHz.
%n
Is
the
channel
frequency
in
GHz.
linkDown
3
critical
Indicates
that
the
radio
link
is
down.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Radio
Link
‐
Out
of
Sync.
The
reason
is:
%s.
%s
Is
the
reason.
detectIDU
4
normal
Indicates
that
the
IDU
was
detected.
Raised
by
both
sides
of
the
link.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
IDU
of
Type
%s
was
Detected.
%s
Is
the
type
of
the
IDU.
disconnectIDU
5
major
Indicates
that
the
IDU
was
disconnected.
Raised
by
both
sides
of
the
link.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
IDU
Disconnected.
mismatchIDU
6
major
Indicates
a
mismatch
between
the
IDUs.
Raised
by
the
master
only.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
IDUs
Mismatch:
One
Side
is
%s
and
the
Other
is
%s.
%s
Is
the
type
of
the
IDU.
openedServices
7
normal
Indicates
that
services
were
opened.
Raised
by
the
master
only.
Contains
3
parameters:
1
‐
Description:
%n2
out
of
%n1
Requested
TDM
Trunks
have
been
Opened
2
‐
%n1:
Is
the
requested
number
of
TDM
truncks
3
‐
%n2:
Is
the
actual
number
of
TDM
trunks
that
were
opened
closedServices
8
normal
Indicates
that
services
were
closed.
Raised
by
the
master
only.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
TDM
Service
has
been
closed.
The
reason
is:
%s.
%s
Is
the
reason.
incompatibleODUs
9
critical
Indicates
that
the
ODUs
are
incompatible.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Incompatible
ODUs.
incompatibleIDUs
10
major
Indicates
that
the
IDUs
are
incompatible.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Incompatible
IDUs.
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......