RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
40
MIB
Traps
Chapter
C
hsuViolatedState
29
normal
Indicates
(on
the
HSU
side)
that
the
HSU
is
is
violated
state
hbsUnregisteredSynchronizedHsu
30
normal
Indicates
an
unregistered
HSU
has
been
synchronized.
hbsUnregisteredUnsynchronizedHsu
31
normal
Indicates
an
unregistered
HSU
lost
synchronization.
cableQuality
32
normal
1Gbps
rate
is
not
supported
due
to
bad
line
quality.
httpAuthentication
33
normal
HTTP
Authentication
Failure.
telnetAuthentication
34
normal
Telnet
Authentication
Failure.
tdmServiceAlarm
100
major
Indicates
that
TDM
Service
is
in
alarm
state.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
TDM
Service
‐
Alarm.
ethServiceClosed
101
major
Indicates
that
Ethernet
Service
is
closed.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Ethernet
Service
is
closed.
ethServiceNotPermitted
102
major
Indicates
that
Ethernet
Service
is
not
permitted.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
A
valid
IDU
could
not
be
detected
at
%s.
Please
check
your
configuration.
%s
‐
Is
the
Local
Site
name
or
Remote
Site
name
or
both
sides
of
the
Link.
encryptionAlarm
103
major
Indicates
an
encryption
key
mismatch.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Encryption
Status
‐
Failed.
No
Services
are
available.
changeLinkPasswordAlarm
104
major
Indicates
that
a
failure
has
occurred
while
attempting
to
change
the
Link
Password.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Failed
to
change
the
Link
Password
at/on:
%s.
%s
‐
Is
the
Local
Site
name
or
Remote
Site
name
or
both
sides
of
the
Link.
externalAlarmInPort1Alarm
105
major
The
trap
is
sent
every
time
an
alarm
occurs
in
the
External
Alarm
Input
of
port
#1.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
External
Alarm
1
‐
<User
Text>
‐
Alarm.
externalAlarmInPort2Alarm
106
major
The
trap
is
sent
every
time
an
alarm
occurs
in
the
External
Alarm
Input
of
port
#2.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
External
Alarm
2
‐
<User
Text>
‐
Alarm.
bitFailedAlarm
107
major
The
trap
is
sent
if
there
is
no
way
to
recover
from
the
situation.Contains
two
parameters:
1
‐
Description:
ODU
power
up
built
in
test
failed.
Error
code
is:
%n
2
‐
%n
number
wrongConfigurationLoadedAlarm
108
major
The
trap
is
sent
if
there
is
a
way
to
recover
from
the
situation.Contains
two
parameters:
1
‐
Description:
Wrong
configuration
loaded.
Error
code
is:
%n
2
‐
%n
number
lanPort1DisconnectedAlarm
109
major
Indicates
the
LAN
port
1
status
changed
to
disconnected.Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
LAN
port
1
status
changed
to
disconnected.
lanPort2DisconnectedAlarm
110
major
Indicates
the
LAN
port
2
status
changed
to
disconnected.Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
LAN
port
2
status
changed
to
disconnected.
mngPortDisconnectedAlarm
111
major
Indicates
the
management
port
status
changed
to
disconnected.Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Management
port
status
changed
to
disconnected.
Table
C
‐
3:
MIB
Traps
(Sheet
3
of
8)
Name
ID
Severity
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......