RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
42
MIB
Traps
Chapter
C
cbwMismatch
130
major
Indicates
that
a
Channel
Bandwidth
mismatch
was
detected.Contains
two
parameters:
1
‐
Description:
Channel
Bandwidth
Mismatch:
one
side
is
%n0
MHz
and
the
other
is
%n1
MHz.
%n0
is
the
local
Channel
Bandwidth
value
in
MHz.
%n1
is
the
remoet
Channel
Bandwidth
value
in
MHz.
gpsNotSynchronized
131
major
Indicates
that
the
GPS
is
not
synchronized
with
satellites.
Pulses
are
self
generated.
pdTooHighDueCbwLimitations
132
major
Indicates
that
link
cannot
be
established
because
link
range
is
too
large
for
channel
bandwidth.
hbsEncryptionAlarm
133
major
Indicates
an
encryption
key
mismatch.
Contains
a
single
parameter
which
is
its
description
including
the
HSU's
name
hbsEhServiceClosedToHsu
134
major
Indicates
an
encryption
key
mismatch.
Contains
a
single
parameter
which
is
its
description
including
the
HSU's
name
hbsUnsynchronizedHsuAlarm
135
warning
Indicates
a
registered
HSU
lost
synchronization.
hbsInactiveHbsAlarm
136
major
Indicates
HBS
is
InActive.
incompatibleHsu
137
critical
Indicates
that
the
HSU
is
not
compatible
to
HBS.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Incompatible
ODUs.
hsuUnsupportedBeacon
138
warning
Indicates
an
unsupported
beacon
has
arrived
at
HSU
lanPortDisconnectedAlarm
139
major
Indicates
the
LAN
port
status
changed
to
disconnected.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
LAN
port
status
changed
to
disconnected.
poePortDisconnectedAlarm
140
major
Indicates
the
POE
port
status
changed
to
disconnected.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
POE
port
status
changed
to
disconnected.
poePowerConsumptionAlarm
141
major
Indicates
the
POE
Power
Consumption
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
POE
consumption
above
allowed
maximum.
port
closed.
hobupFaultyStateAlarm
149
major
This
Alarm
will
indicate
that
the
Hot
Backup
module
is
in
faulty
state.
1
‐
Description:
Hot
Backup
fault
detected:
%s
unit.
%s
‐
Primary
Or
Secondary
Unit
gpsOverCurrentAlarm
150
major
Indicates
the
GPS
Antenna
current
consumption
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Antenna
current
consumption
above
allowed
maximum.
GPS
closed.
gpsCommunicationFailiureAlarm
151
major
Indicates
the
GPS
data
isn't
received.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Communication
failiure.
temperatureThresholdAlarm
152
major
Indicates
the
board
temperature
is
above
allowed
maximum.
Contains
a
single
parameter,
which
is
its
description:
1
‐
Description:
GPS
Antenna
current
consumption
above
allowed
maximum.
GPS
closed.
localRouterDiscoveryStatus
153
major
This
Alarm
will
indicate
that
we
have
no
connection
with
Track
side
router.
1
‐
Description:
MacLearningUpdate
detected
disconnection
with
Track
side
router
%s
%s
‐
Default
gateway
IP
Table
C
‐
3:
MIB
Traps
(Sheet
5
of
8)
Name
ID
Severity
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......