RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
29
Private
MIB
Parameters
winlink1000IduTdmLoopbackConfig
RW Loop
back
configuration
table.
Each
of
the
trunks
can
be
set
Normal
Line
loop
back
or
Reverse
line
loop
back.
A
change
is
effective
immediately.
winlink1000IduTdmLineStatus
RO
Line
status.
winlink1000IduTdmCurrentTable
N/A IDU
TDM
Links
Statistics
table.
winlink1000IduTdmCurrentEntry
N/A IDU
TDM
Links
Statistics
table
entry.
INDEX
{
winlink1000IduTdmCurrentIndex
}
winlink1000IduTdmCurrentIndex
RO
Table
index
(Same
as
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks
RO
Number
of
correct
blocks
transmitted
to
the
line.
winlink1000IduTdmCurrentDrops
RO
Number
of
error
blocks
transmitted
to
the
line.
winlink1000IduTdmCurrentTxClock
RW TDM
Transmit
Clock.
A
change
is
effective
after
re
‐
activation
of
the
TDM
service.
winlink1000IduTdmCurrentBlocksHi
gh
RO
High
part
of
the
64
bits
counter
Current
Blocks
winlink1000IduTdmRemoteQual
RO
Estimated
average
interval
between
error
second
events.
The
valid
values
are
1
‐
2^31
where
a
value
of
‐
1
is
used
to
indicate
an
undefined
state.
winlink1000IduTdmRemoteQualEva
l
RO
Estimated
average
interval
between
error
second
events
during
evaluation
process.
The
valid
values
are
1
‐
2^31
where
a
value
of
‐
1
is
used
to
indicate
an
undefined
state.
winlink1000IduTdmSrvEval
RW Evaluated
TDM
service
bit
mask.
Setting
this
parameter
to
value
that
is
bigger
than
the
activated
TDM
service
bit
mask
will
execute
the
evaluation
process
for
30
seconds.
Setting
this
parameter
to
0
will
stop
the
evaluation
process
immediately.
winlink1000IduTdmBackupAvailabl
eLinks
RO
Number
of
TDM
backup
trunks.
winlink1000IduTdmBackupTable
N/A IDU
TDM
Links
Statistics
table.
winlink1000IduTdmBackupEntry
N/A IDU
TDM
Links
Statistics
table
entry.
INDEX
{
winlink1000IduTdmBackupIndex
}
winlink1000IduTdmBackupIndex
RO
Table
index.
winlink1000IduTdmBackupMode
RW TDM
backup
mode:
Enable
or
Disable
where
the
main
link
is
the
air
link
or
the
external
link.
Changes
will
be
effective
immediatly.
winlink1000IduTdmBackupCurrentA
ctiveLink
RO
TDM
backup
current
active
link:
N/A
air
link
is
active
or
external
link
is
active.
winlink1000IduTdmJitterBufferSize
RW TDM
Jitter
Buffer
Size.
The
value
must
be
between
the
minimum
and
the
maximum
TDM
Jitter
Buffer
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferDefa
ultSize
RO
TDM
Jitter
Buffer
Default
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferMinS
ize
RO
TDM
Jitter
Buffer
Minimum
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferMax
Size
RO
TDM
Jitter
Buffer
Maximum
Size.
The
units
are
0.1
x
millisecond.
winlink1000IduTdmJitterBufferSizeE
val
RW TDM
Jitter
Buffer
Size
for
evaluation.
The
value
must
be
between
the
minimum
and
the
maximum
TDM
Jitter
Buffer
Size.
The
units
are
0.1
x
millisecond.
Table
C
‐
2:
Private
MIB
Parameters
‐
HBS
(Sheet
24
of
33)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......