RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
68
Private
MIB
Parameters
winlink1000OduServiceVlanTblProv
iderTPID
RW Holds
the
Provider
TPID
that
is
used
in
all
provider
operations.
winlink1000HbsServiceQoSMode
RW Quality
of
Service
mode.
winlink1000HbsServiceQoSVlanQGr
oupsStr
RW Frame
classification
according
to
VLAN
priority
(all
4
groups
separated
by
comma).
winlink1000HbsServiceQoSDiffserv
QGroupsStr
RW Frame
classification
according
to
Diffserv
(all
4
groups
separated
by
comma).
winlink1000HbsServiceQoSMaxRtQ
uePct
RO
Maximal
percent
for
RT
and
NRT
queues.
winlink1000HbsServiceQoSTable
N/A Holds
the
QoS
operations
towards
all
the
registered
HSUs.
winlink1000HbsServiceQoSEntry
N/A HBS
service
QoS
table
entry.
INDEX
{
winlink1000HbsServiceQoSIndex
}
winlink1000HbsServiceQoSIndex
RO
HBS
service
QoS
table
index.
winlink1000HbsServiceQoSConfAd
minState
RW QoS
administrative
state.
The
valid
values
are:
enabled
(1)
disabled
(2).
winlink1000HbsServiceQoSConfUp
QueMir
RW Private
MIR
for
each
QoS
group
of
the
Uplink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSConfUp
QueWeight
RW Weight
in
percent
for
each
QoS
group
of
the
Uplink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSConfDo
wnQueMir
RW Private
MIR
for
each
QoS
group
of
the
Downlink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSConfDo
wnQueWeight
RW Weight
in
percent
for
each
QoS
group
of
the
Downlink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSUpTtlMs
RW TTL
in
mili
second
for
each
QoS
group
of
the
Uplink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSDownTtl
Ms
RW TTL
in
mili
second
for
each
QoS
group
of
the
Downlink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSUpStrict
RW Strict
QOS
Boolean
indication
for
each
QOS
group
of
the
Uplink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceQoSDownStr
ict
RW Strict
QOS
Boolean
indication
for
each
QOS
group
of
the
Downlink
direction
(4
values
separated
by
comma).
winlink1000HbsServiceMobilitySup
ported
RO
Mobility
Support
(1
=
Not
supported
2
=
Supported
3
‐
Transport
supported)
winlink1000HbsServiceMaxNumOf
HSUs
RO
Holds
the
maximum
number
of
registered
HSUs
in
the
HBS.
winlink1000HbsPerfMonThreshTabl
e
N/A Holds
the
performance
monitor
thresholds
towards
all
the
registered
HSUs.
winlink1000HbsPerfMonThreshEntr
y
N/A HBS
performance
monitor
threshold
table
entry.
INDEX
{
winlink1000HbsPerfMonThreshIndex
}
winlink1000HbsPerfMonThreshInde
x
RO
HBS
performance
monitor
threshold
table
index.
winlink1000HbsPerfMonTxThresh1
RW HBS
performance
monitor
transmit
power
threshold.
winlink1000HbsPerfMonRxThresh1
RW HBS
performance
monitor
receive
power
threshold
1.
winlink1000HbsPerfMonRxThresh2
RW HBS
performance
monitor
receive
power
threshold
2.
winlink1000HbsPerfMonBBERThres
h1
RW HBS
performance
monitor
BBER
threshold.
Table
C
‐
3:
Private
MIB
Parameters
‐
HSU
(Sheet
30
of
33)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......