RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
71
Private
MIB
Parameters
winlink1000HsuAirAlignmentLastRe
portRssChain3
RO
RSS
on
chain
3.
winlink1000HsuAirAlignmentLastRe
portMcsIndexUp
RO
MCS
index
of
the
link
in
the
uplink
direction.
winlink1000HsuAirAlignmentLastRe
portMcsIndexDown
RO
MCS
index
of
the
link
in
the
downlink
direction.
winlink1000HsuAirAlignmentLastRe
portState
RO
State
of
the
Evaluation
1
Finished
successfully
2
Partial
Evaluation
(Timeout
Exceeded)
3
Evaluation
Aborted
(Timeout
Exceeded)
4
Evaluation
aborted
(Unstable
Antenna)
5
Evaluation
aborted
(Sync
Lost)
6
Evaluation
aborted
(External
command)
7
Evaluating.
winlink1000HsuServiceCommandSt
r
1.3.6.1.4.1.4458.1000.4.2.1
DisplayString
RW Ability
to
perform
special
command
in
the
HSU.
Format
(string):
Operation
Param1
Param2
....|
ParamN.
winlink1000HsuServiceHsuType
1.3.6.1.4.1.4458.1000.4.2.2
Integer
RW HSU
type
(1
=
Fixed
2
=
Stationary
3
=
Mobile
4
=
Transport)
winlink1000HsuServiceHsuLevel
1.3.6.1.4.1.4458.1000.4.2.3
Integer
RW HSU
level
(1
..
4)
winlink1000HsuEthernetPoESuppor
ted
1.3.6.1.4.1.4458.1000.4.3.1.
1
Integer
RO
Indicated
if
this
HSU
has
special
port
for
PoE
devices.
winlink1000HsuEthernetPoETempe
rature
1.3.6.1.4.1.4458.1000.4.3.1.
2
Integer
RO
Holds
the
temperature
(Celsius)
of
the
POE
component.
winlink1000HsuEthernetPoEEquCo
nsumption
1.3.6.1.4.1.4458.1000.4.3.1.
3
Integer
RO
Holds
the
consumption
of
the
connected
equipment
(milliampere).
winlink1000HsuEthernetPoEEquVol
tage
1.3.6.1.4.1.4458.1000.4.3.1.
4
Integer
RO
Holds
the
voltage
of
the
connected
equipment
(Volt).
winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString
RO
Trap's
Description.
Used
for
Trap
parameters.
winlink1000GeneralTrapSeverity
1.3.6.1.4.1.4458.1000.100.2 Integer
RO
Trap's
Severity.
Used
for
Trap
parameters.
winlink1000GeneralCookie
1.3.6.1.4.1.4458.1000.100.3 DisplayString
RW Reserved
for
the
Manager
application
provided
with
the
product
used
for
saving
user
preferences
affecting
ODU
operation.
winlink1000GeneralEcChangesCoun
ter
1.3.6.1.4.1.4458.1000.100.4 Integer
RO
This
counter
is
initialized
to
0
after
a
device
reset
and
is
incremented
upon
each
element
constant
write
operation
via
SNMP
or
Telnet.
winlink1000GeneralTelnetSupport
1.3.6.1.4.1.4458.1000.100.5 Integer
RW Enable/Disable
Telnet
protocol.
winlink1000GeneralWISupport
1.3.6.1.4.1.4458.1000.100.6 Integer
RW Enable/Disable
Web
Interface
protocol.
Mandatory
Disabled
‐
No
option
to
enable
the
feature.
Mandatory
Enabled
‐
No
option
to
disable
the
feature.
winlink1000GeneralSNMPSupport
1.3.6.1.4.1.4458.1000.100.7 Integer
RW Enable/Disable
SNMP
protocols
Table
C
‐
3:
Private
MIB
Parameters
‐
HSU
(Sheet
33
of
33)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......