RADWIN
5000
HPMP
User
Manual
Release
3.5.70
C
‐
75
MIB
Traps
externalAlarmInPort4Alarm
113
major
The
trap
is
sent
every
time
an
alarm
occurs
in
the
External
Alarm
Input
of
port
#4.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
External
Alarm
4
‐
<User
Text>
‐
Alarm.
swVersionsMismatchFullCompatibilityAlarm
114
warning
The
trap
is
sent
if
SW
versions
mismatch
with
full
link
functionality.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
full
link
functionality
swVersionsMismatchRestrictedCompatibilityAlarm
115
minor
The
trap
is
sent
if
SW
versions
mismatch
with
restricted
link
functionality.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
restricted
link
functionality
swVersionsMismatchSoftwareUpgradeRequired
116
major
The
trap
is
sent
if
SW
versions
mismatch
and
SW
upgrade
is
required.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
Software
upgrade
required
swVersionsIncompatible
117
critical
The
trap
is
sent
if
SW
versions
are
incompatible.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
SW
Versions
incompatible
hssMultipleSourcesDetectedAlarm
118
major
Indicates
that
multiple
sync
pulse
sources
were
detected.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
multiple
sync
sources
were
detected.
hssSyncToProperSourceStoppedAlarm
119
major
Indicates
that
synchronization
to
a
proper
sync
pulse
source
was
stopped.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
sync
pulse
‐
Down.
The
reason
is:
%s.
%s
‐
Is
the
reason
for
the
sync
down.
hssSyncPulseDetectedAlarm
120
major
Indicates
that
HSS
additional
sync
pulse
was
detected.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
additional
sync
pulse
was
detected.
tdmBackupAlarm
121
major
Indicates
that
the
TDM
backup
link
was
activated.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
TDM
backup
alarm
‐
backup
link
was
activated.
linkLockUnauthorizedRemoteODU
122
major
Indicates
that
the
remote
ODU
is
unauthorized.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Unauthorized
remote
ODU
connection
rejected.
linkLockUnauthorizedODU
123
major
Indicates
that
the
ODU
is
unauthorized.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Unauthorized
ODU
connection
rejected.
hotStandbyAlarm
124
major
Indicates
that
the
hot
standby
secondary
link
was
activated.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Secondary
Link
Is
Active.
sfpInsertion
126
normal
Indicates
that
a
device
was
inserted
to
SFP
Port
sfpPort1DisconnectedAlarm
127
major
Indicates
the
SFP
port
1
status
changed
to
disconnected.Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
SFP
port
1
status
changed
to
disconnected.
ringRplStateActiveAlarm
128
major
RPL
state
changed
to
Active.
desiredRatioCanNotBeAppliedAlarm
129
normal
Indicates
Desired
UL/DL
RAtio
Can
Not
Be
Applied.
cbwMismatch
130
major
Indicates
that
a
Channel
Bandwidth
mismatch
was
detected.Contains
two
parameters:
1
‐
Description:
Channel
Bandwidth
Mismatch:
one
side
is
%n0
MHz
and
the
other
is
%n1
MHz.
%n0
is
the
local
Channel
Bandwidth
value
in
MHz.
%n1
is
the
remoet
Channel
Bandwidth
value
in
MHz.
gpsNotSynchronized
131
major
Indicates
that
the
GPS
is
not
synchronized
with
satellites.
Pulses
are
self
generated.
Table
C
‐
4:
MIB
Traps
(Sheet
4
of
8)
Name
ID
Severity
Description
Summary of Contents for 5000 HPMP
Page 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Page 21: ...Part 1 Basic Installation Release 3 5 70...
Page 69: ...Part 2 Sector Installation Release 3 5 70...
Page 155: ...Part 3 Sector Management Release 3 5 70...
Page 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Page 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Page 290: ...Part 4 Site Synchronization Release 3 5 70...
Page 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Page 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Page 354: ...Part 6 Field Installation Topics Release 3 5 70...
Page 396: ...Part 7 Product Reference Release 3 5 70...
Page 517: ......