Configuration via Telnet
WinLink User and Installation Guide
Version 1.750
5-101
Table
5-2: Telnet Commands
Command Explanation
display inventory
Displays ODU product name, Name, Location,
hardware and software revisions, uptime, MAC
address, IDU product name, IDU software and
hardware revisions
Display management
Displays IP, Subnet, Gateway, Traps table
display link
Displays State, SSID, Channel BW, RSS, TSL,
Frequency/ACS, DFS, Rate/ARA, Distance
display Ethernet
Displays Bridge Mode, Aging time, Port table (State,
Status and action)
display tdm
Displays Clock Mode, Master Clock Mode, Current
Clock, Quality[1], TDM table (Line status, Error
Blocks)
display ntp
Displays Time, Server and Offset
set ip <ipaddr> <subnetMask>
<gateway>
Set the ODU IP address, subnet mask and gateway
The user must reset the ODU after the command
completion
set trap <index:1-10> <ipaddr>
<port:0-65535>
Set a specific trap from the traps table (set trap 3
10.0.0.133 162)
set readpw <oldpasswd> <passwd>
Set the read access password (read community)
set writepw <oldpasswd> <passwd>
Set the read-write access password (read-write
community)
set trappw <oldpasswd> <passwd>
Set the trap community string
set buzzer <mode:0=OFF,1 =ON>
Toggle the buzzer mode (0 – off, 1 – on)
set tpc<power:Value between minimal
TX power, and maximal TX power>
Set the ODU transmit power. If a wrong value is
entered, both min and max values shall be displayed
in the error reply
set bridge <mode:0=Bridging OFF,1=
Bridging ON >
Set the ODU bridge mode (0 – off, 1 – on)
reboot
Reset both the IDU and the ODU. The user shall be
prompt that the command will reset the card and
that he has to reconnect the telnet session after TBD
seconds.
help
Displays the available commands