Technical Specifications
WinLink User and Installation Guide
Version 1.750
2-29
Air Interface
Technology
OFDM
IDU (green)
IDU-C status
ODU (green/red)
ODU-to-IDU link status
LINK (green/red)
Link status
SERVICE (green/red)
E1/T1 signal status
Power
Source
IDU-E: 100–240 VAC via external AC/DC converter
IDU-C: 100–240 VAC via AC cable
-20 to –60 VDC
O-PoE: 100–240 VAC via attached (pigtail) AC cable
PoE-8: 100–240 VAC via AC cable
-20 to –60 VDC Max
Note
: Both AC and DC power sources can be
connected simultaneously but only one source will supply
the power
Power Received by
the ODU
-42 to -60 VDC
Power Consumption
ODU plus IDU-E or IDU-E-AL or IDU-R – 10W max
ODU plus IDU-C – 14W max
AIND – 14 max
O-PoE plus ODU – 25W max
PoE-8 plus 8 ODU units – 60W max
Connector
IDU-E 2-pin
IDU-C AC – 3-pin IEC connector
DC – 3-pin terminal block
Connector
DB-9 female for IDU-C/AIND/PoE-8
DB-25 female for IDU-E-AL/IDU-R
Alarm
Connector
Electrical Characteristics Dry Contact, 30V/2A
Max input current, 0.01A at 0.5W (R=5K)
Sync Connector
Connector
RJ-11 for AIND
Physical
Outdoor Unit
ODU with integrated antenna
Height
24.5 cm / 9.3 in
30.5 cm / 12 in
Width
13.5 cm / 5.13 in
30.5 cm / 12 in
Depth
4.0 cm / 1.57 in
5.8 cm / 2.3 in
Weight
1.0 kg / 2.2 lb
1.5 kg / 3.3 lb
Indoor Unit
IDU-E
IDU-C/AIND/PoE-8
Height
4.5 cm (1.7 in) 1U
4.5 cm (1.7 in) 1U