DM240XR High-Speed Digital Modulator
Appendix B
TM120 – Rev. 1.1
B-
15
radLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Minor Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = FIFO overflow/underflow error
Bit 5 = Loss of frame synchronization
"
::= { radSNMP_Mod_Status 5 }
radLatchedCommonAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Common Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMP_Mod_Status 6 }
radRevisionNumber OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS optional
DESCRIPTION
"M&C Revision number."
::= { radSNMP_Mod_Status 7 }
radPlus5Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"+5V monitor with implied decimal point.
For example, a value of 51 repr5.1 Volts."
::= { radSNMP_Mod_Status 8 }
radPlus12Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"+12V monitor with implied decimal point.
For example, a value of 119 repr11.9 Volts."
::= { radSNMP_Mod_Status 9 }
radMinus12Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (-255..0)
ACCESS read-only
STATUS current
DESCRIPTION
"-12V monitor with implied decimal point.
For example, a value of -122 represents -12.2 Volts."
::= { radSNMP_Mod_Status 10 }
radTemperature OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-only
STATUS optional
DESCRIPTION
"Temperature monitor with implied decimal point.
For example, a value of 490 represents 49.0 C"
Summary of Contents for DM240XR
Page 2: ......
Page 10: ...Table of Contents DM240XR High Speed Digital Modulator x TM120 Rev 1 1 ...
Page 12: ...Introduction DM240XR High Speed Digital Modulator 1 2 TM120 Rev 1 1 ...
Page 16: ...Installation DM240XR High Speed Digital Modulator 2 4 TM120 Rev 1 1 ...
Page 19: ...DM240XR High Speed Digital Modulator Theory of Operation TM120 Rev 1 1 3 3 ...
Page 55: ...User Interfaces DM240XR High Speed Digital Modulator 4 36 TM120 Rev 1 1 ...
Page 67: ...Rear Panel Interfaces DM240XR DVB High Speed Digital Modulator 5 12 TM120 Rev 1 1 ...
Page 69: ...Maintenance and Troubleshooting DM240XR High Speed Digital Modulator 6 2 TM120 Rev 1 1 ...
Page 79: ...Technical Specifications DM240XR High Speed Digital Modulator 7 10 TM120 Rev 1 1 ...
Page 103: ...Appendix A DM240XR High Speed Digital Modulator A 24 TM120 Rev 1 1 ...
Page 124: ...DM240XR High Speed Digital Modulator Appendix B TM120 Rev 1 1 B 21 ...