AN186 - Rev. 1.0
DMD2050 FTP
Page
9
16.
Delete all files and folders under \MC\ACCEPTED on the compact flash (note: files within
folders will need to be deleted prior to deleting folders)
17.
Copy the contents of \MC\ACCEPTED folder from the \dmd2050\rev-xx folder on your
hard drive to the \MC\ACCEPTED folder of the compact flash.
18.
Delete all files and folders under \MC\PENDING on the compact flash (note: files within
folders will need to be deleted prior to deleting folders)
19.
The next time the DMD2050 is powered up, it will contain the new firmware. The new
firmware can be verified on the front panel at power up or by looking in the SYSTEM,
HW/FW CONFIG/M&C REV menu. The new firmware will read F05058-xx (where xx is
the latest revision of software).
20.
Place the file Xreset (no content) in the compact flash root if a reboot is desired when
connection is closed.