SINGLE CH ANNE L LOOP DETE CTOR 

OPERATING INSTRUCTIONS 

General 

The Model H2 is a single channel detector with a solid state Detect Output and a 
solid state Fail Output.  

Please verify source voltage before applying power.

  

The Model H2 will operate on voltages between 8 and 30 VDC with a maximum 
current requirement of 45 mA. 

II

 

Indicators and Controls 

Power / Detect / Fail LEDs 

The detector has one green and two red LED indicators used to provide 
indications  of the detector’s power status, output state,  and/or loop failure 
conditions.  The table below lists the various indications and their meanings. 

Status  POWER LED (Green)  DETECT LED (Red) 

FAIL LED (Red) 

Off 

No power 

Detect Output Off 

Loop OK 

On 

Power to detector 

Detect Output On 

N/A 

Flash 

N/A 

2 Hz (50% duty cycle) 

Delay timing 

4 Hz (50% duty cycle) 

Extension timing 

1 Hz (50% duty cycle) 

Loop Failure 

One flash every five seconds 

Prior Loop Failure 

ii 

Rotary Switch (Sensitivity) 

The eight-position rotary switch selects one of eight (8) sensitivity levels as 
shown in the table below.  0 is lowest and 7 is highest, with normal (factory 
default) being 4.  Use the lowest sensitivity setting that consistently detects the 
smallest vehicles.  Using  higher  than necessary  sensitivity levels may result in 
false detections. 

Position 

4 * 

-

L/L 

2.56%  1.28%  0.64%  0.32%  0.16% *  0.08%  0.04%  0.02% 

*  Factory default setting.

 