PROGRAMMING OF IAQRAE
4-3
4.1 Enter & Exit Programming Mode
Table 4.2 Programming Keys
[MODE]
Exit menu when pressed momentarily
Exit data entry mode when pressed and held
for one second
[Y/+]*
Increase numerical value for data entry
Answer “yes”
[N/-]*
Decrease numerical value for data entry
Answer “no”
* For rapid scrolling, press and hold these keys.
To Enter
1. Turn the IAQRAE monitor on.
2. Press and hold [MODE] and [N/-] simultaneously for three
seconds to enter Programming Mode. This delay prevents
the user from entering Programming Mode by accident.
3. Security Level 0 or Level 2 - the monitor will enter
Programming Mode and the first menu item “Calibrate
Monitor?” will display.
4. Security Level 1 - “Enter Password = 0000” will display with
the far left digit flashing. The user enters password starting
from the flashing digit.
Note:
Prior to factory shipment, the IAQRAE monitor was
installed with “0000” as the default password. For added
security, “0000” is always displayed instead of the actual
password.
5. If the digit value is not “0”, use [Y/+] or [N/-] to increase or
decrease digit value. Press [MODE] to confirm digit value.
Display shows actual digit entered and moves the flashing
cursor to the next digit to the right.
6. Repeat Step 5 until all four digits are entered. Then press
and hold [MODE] for one second.