background image

 

Duonet User Instructions 

 

 
 
 

16 

 
This  function  allows  the  disablement  or  enablement  of  programmed  Network  operation  at 
that  control  panel.  The  transmission  and  /  or  the  receipt  of  signals  may  be  disabled  as 
required.  The  control  panel  will  indicate  that  disablements  are  present  and  a  disablement 
event will be recorded to log. 

 
 
Disable / Enable: Default to all enabled  

 

This function enables any device / action that may have been disabled, and all programmed 
actions  are  reinstated.  The  control  panel  event  log  will  indicate  that  all  actions  have  been 
reinstated. 

 
 

Set Time and Date 

 

This allows the time and date to be adjusted. These settings will need to be re-entered after 
the complete removal of power, as the system will simply resume from the point that power 
was removed. 
 
 

Test Modes: Silent Test 

 

The Silent Test function allows the selection of one or more detection-zones to operate in a 
‘silent  one-man  walk  test  mode’.  On  triggering  a  device  the  device  LED  operates  and  the 
event is recorded into the event log as a test activation, but the sounder does not sound and 
the  control  panel  does  not  show  an  alarm.  After  approximately  5  seconds  the  system  will 
reset the device, and another may be tested. The control panel event log will indicate that a 
test mode has been selected. 

 
 

Test Modes: Local Audible Test 

 

The  Local  Audible  Test  function  allows  the  selection  of  one  or  more  detection-zones  to 
operate  in  a  ‘one-man  walk  test  mode  with  local  sound’.  On  triggering  a  device  the  device 
LED  operates,  the  sounder  within  that  device  operates  and  the  event  is  recorded  into  the 
event  log  as  a  test  activation,  but  the  control  panel  does  not  show  an  alarm.  After 
approximately 5 seconds the system will reset the device, and another may be tested. The 
control panel event log will indicate that a test mode has been selected. 

 
 
Test Modes: Full System Test 

 

The Full System Test function allows the entire system to operate in a simple one-man walk 
test mode. On triggering a device the device LED operates and the event is recorded into the 
event log, all the assigned sounders operate for 10 seconds and the control panel indicates 
an alarm. After approximately 10 second the system will reset the device, and another may 
be tested. The control panel event log will indicate that a test mode has been selected. 
 
Please  note,  with  the  system  test  mode,  only  the  sounders  assigned  to  operate  from  that 
device will sound, and any delays will still be present. i.e., if a delay of 2 minutes is present, 
the system will have been reset before the sounders activate. 

 
 

Test Modes: End all Tests  

 

This  function  ends  any  test  routine  that  may  have  been  activated,  and  all  programmed 
actions  are  reinstated.  The  control  panel  event  log  will  indicate  that  all  actions  have  been 
reinstated. 

 
 

Summary of Contents for duonet

Page 1: ...26 0810 Issue1 Fire Detection Alarm System Control Panel V1 000 User Guide TO BE RETAINED BY USER...

Page 2: ...of such contents Due to the complexity and inherent importance of a life risk type system then training on this equipment is essential and commissioning should only be carried out by competent person...

Page 3: ...ol Panel Front 8 Fire Alarm Controls 9 System Controls 9 Access Levels and Codes 9 Fire Alarm 10 On hearing the alarm 10 Accessing the controls 10 Silencing the alarms 10 Resetting the system 10 Sound...

Page 4: ...or servicing contractor or servicing contractor or a member of the user s staff who has received suitable training from the manufacturer or supplier Understanding the Equipment What is Duonet Duonet i...

Page 5: ...itioning may be shut down when the alarm sounds Make sure that you know what happens when the fire alarm operates as this can affect routine system testing The system is powered from the mains supply...

Page 6: ...ervices interfaces to avoid disruption to the occupants In any case the panel should provide audible and visual indication that parts of the system are disabled Daily Check that the panel indicates no...

Page 7: ...tion by the user after any false alarm The user can assist the servicing company in the identification of false alarms by observing the following Always make a note of all illuminated indicators and m...

Page 8: ...81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 FIRE FAULT DISABLED TEST PO...

Page 9: ...require it For simple indication the status of the Controls Enabled light will show the level selected as follows Access Level Description Shift LED Key Operation Default Code 1 NORM Normal OFF YES N...

Page 10: ...heard on each key press and when successfully entered the CONTROLS ENABLED light will light up continuously and USER or SUPR is displayed in the top right hand corner You are now in Access Level 2A Us...

Page 11: ...s SILENCE BUZZER The fault buzzer will be silenced Exit Access Level 2A User or Access Level 2B Supervisor In order to prevent unauthorised access to the system return to Access Level 1 Normal However...

Page 12: ...Access Level 2B Supervisor see section on operation Alarm condition still present Remove cause of alarm eg replace broken glass in call point Buzzer sounding FAULT LED lit Fault or abnormal condition...

Page 13: ...t be entered in order access any of the menus Access Level 2A User Controls Enabled LED off At Access Level 2A User the main Fire Alarm Controls are enabled and the following System Controls are acces...

Page 14: ...The Active Disablement Log will display any current disablement These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys 1 Test Display 2 View Logs 1 Current War...

Page 15: ...will be recorded to log the device LED will still operate when activated and an event will be recorded to log but no programmed actions will occur The sounder within the device will still operate if...

Page 16: ...st Modes Local Audible Test The Local Audible Test function allows the selection of one or more detection zones to operate in a one man walk test mode with local sound On triggering a device the devic...

Page 17: ...ion allows the user to override any pre programmed Day Night timing information and force the system into the more sensitive Night Mode This will cause the buzzer to sound and a disablement to be writ...

Page 18: ...lashing Either a battery supply charger fault has been detected check the fuse and the battery voltages or a mains supply fault has been detected check for a 24V AC supply on the PCB Ac terminals 9 EA...

Page 19: ...m state and sending a Technical Alarm signal to the panel 18 ALARM CONFIRMATION Flashing A smoke detector is in the alarm confirmation state awaiting confirmation or reset 19 OUTPUTS DELAYED Amber Con...

Page 20: ...Duonet User Instructions 20 Log Book Record all fire and fault events whether or not an engineer was called Event Log Time Zone Device Event Action Initials...

Page 21: ...Duonet User Instructions 21 Time Zone Device Event Action Initials...

Page 22: ...Duonet User Instructions 22 Time Zone Device Event Action Initials...

Page 23: ...Duonet User Instructions 23 Time Zone Device Event Action Initials...

Page 24: ...Duonet User Instructions 24 Time Zone Device Event Action Initials...

Page 25: ...Duonet User Instructions 25 Time Zone Device Event Action Initials...

Page 26: ...Duonet User Instructions 26 Time Zone Device Event Action Initials...

Page 27: ...Duonet User Instructions 27 Time Zone Device Event Action Initials...

Page 28: ...uipment Control Panel Duponet V Serial No No of Loops used No of zones used Total No of Devices No of detectors No of call points No of sounders Interfaces Mains Supply Loop ve continuity Loop ve cont...

Reviews: