16.3.1
Changing Network Settings for Monitoring Disk Arrays from
Storage Manager
If a disk array cannot be monitored correctly from Storage Manager due to faults occurring in
performing initialization or erroneous settings, network settings must be changed.
Change disk array network settings using any of the following three procedures.
(1) Changing Network Settings from Storage Manager
If the disk array can be monitored from Storage Manager in spite of wrong network settings, the
disk array unit network settings can be changed from Storage Manager.
Make changes using [Disk Array Setting]
→
[Network] from the menu [File]
→
[Configuration
Setting]
→
[Configuration Setting]
→
[Individual Setting/Reference]. For details, refer to
“Configuration Setting Tool User’s Manual (GUI)”.
If monitoring is not being done by Storage Manager but there is a host connected by FC to the disk
array, changes can also be made using the network relief setting command (iSMnetconf) from the
host. For details, refer to the “Configuration Setting Tool User’s Manual (GUI)”.
-
152
-