The version of the software that you install must support disk arrays that are
connected to the server.
Moreover, if a disk array has RemoteDataReplication configure, the remote disk
array to which it connects must also be supported.
ControlCommand is 32-bit software.
If it will be used in an IA64 server environment, a 32-bit emulator, 32-bit
compatible library, or other package offered by the OS must be installed in advance
in order for the 32-bit software to run. Refer to the “ControlCommand on Linux
Installation Guide” for details.
(1) Login as root or switch to root.
(2) Confirm that none of the following software is installed.
iSMrpl (ReplicationControl)
iSMrcd (ReplicationControl/DisasterRecovery)
iSMsc (SnapControl)
iSMvol (Storage Manager volume list command)
iSMccs (ControlCommandSet or ControlCommand)
rpm -q iSMrpl
rpm -q iSMrcd
rpm -q iSMsc
rpm -q iSMvol
rpm -q iSMccs
If any of these are installed, uninstall them.
(3) Insert the CD on the business server.
For servers on which the CD cannot be used, file transfer iSMccs.rpm from another server.
(4) Mount the CD.
Create the mount directory (For example, /cdrom)
Mount using the mount command
mount -r /dev/cdrom /cdrom
(5) Install using the rpm command.
rpm -ivh /cdrom/LINUX/iSMCCS/iSMccs.rpm
(6) Installation is complete when the message below is output.
Installation completed.
(7) Unmount the CD.
Unmount using the umount command
umount /cdrom
-
68
-
Summary of Contents for Xanadu
Page 16: ...Power Supply Controller xv...
Page 17: ...Battery xvi...
Page 18: ...Disk Enclosure xvii...
Page 19: ...Extended Battery Backup Unit Extended Battery Backup Unit Power Supply xviii...
Page 26: ...This page is intentionally left blank...