13
animals in order to prevent serious damage.
• If the compressor is no longer in use,
always take the plug out of the plug socket.
• Always make sure that compressed-air
hoses are used for compressed air and which
are characterised by a maximum pressure
adjusted to that of the compressor. Do not try
to repair the hose if it is damaged.
3. USE
The compressor is used as a
power supply for pneumatic
machines.Only used indoors!
NB: The information you will
find in this manual has been written to assist
the operator in the use and maintenance of
the compressor. Some illustrations in this
manual show details which may differ from
those of your compressor.
Installation
After having taken the compressor out of
its packaging and having checked that it is
in perfect condition, and having noted that
no damage occurred during transport, the
following acts should be performed. If not yet
fitted, fit the rubber feet and the wheels on the
tank according to the instructions represented
in. Place the compressor on a flat surface or
at a maximum slope of 10°, in a well ventilated
area, protected against atmospheric factors
and not in explosive surroundings. If the
surface area is sloping and smooth, make
sure that the compressor will not move when
in operation. If the surface area is a board or a
shelf of a bookcase, just make sure that they
cannot fall down by securing them properly.
For proper ventilation and effective cooling, it
is important that the compressor is positioned
at least 100 cm from the wall.
Make sure that the compressor is
transported in the right way, do not turn it
upside down and don’t lift it with hooks or
ropes
STARTING UP
• Check whether the mains voltage
corresponds to that indicated on the electrical
specification plate, the permitted tolerance
range should be within 5%.
• Press the switch situated on the upper part
into the “0” position according to the pressure
regulator type fitted on the device.
• Put the plug in the plug socket and start
the compressor up by putting the switch of
the pressure regulator in the “I” position.
The operation of the compressor is fully
automatic.
The pressure regulator will stop the
compressor when the maximum value
has been reached and start it up when the
pressure drops below the minimum value.
Normally the difference in pressure is
approx. 2 Bar/29 psi between the maximum
and the minimum value. For instance - The
compressor will stop when it reaches 8 Bar
(116 psi) (this is the maximum operating
pressure) and will start up automatically when
the pressure within the tank has dropped to
6Bar (87 psi).
The
head/cylinder/transmission
pipe assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns.
ADJUSTING THE OPERATING PRESSURE
It is not necessary continuously to use
the maximum operating pressure, the
compressed-air tools often require less
pressure. With regard to compressors
supplied with a pressure reduction valve it
is necessary to set the operating pressure
properly.
It is possible to set the operating pressure by
using the turning knob on the reduction valve.
• By turning clockwise, the pressure will be
increased.
• By turning anti-clockwise, the pressure will
be reduced.
The compressor has pressure gauge and two
points to connect an air hose:
The set pressure is visible on the manometer
of the reduction valve.
4. MAINTENANCE
Make sure that the plug is removed
from the mains when carrying out maintenance
work on the motor.
Summary of Contents for RD-AC03O
Page 3: ...3 normal minimum...
Page 7: ...7 2 5 C 40 C 70 0 OFF 3 10...
Page 8: ...8 www raider bg 100 5 0 I 2Bar 29Psi 8 116 PSI 6bar 87 PSI 4 0 0 5...
Page 9: ...9 C C2 B1 B2 0 C 6 7 8 50 1 2 9 2002 96...
Page 24: ...24 www raider bg 70 0 OFF No 3 10 100...
Page 25: ...25 5 0 I 2Bar 29Psi 8 116 PSI 6bar 87 PSI 4 0 0 5 C C2 B1 B2...
Page 26: ...26 www raider bg 0 C 6 7 8 50 1 2 9 2002 96...
Page 40: ...40 www raider bg 0 OFF UIT 20 12 13 3 homehold 10 100 cm...
Page 41: ...41 5 0 2 Bar 29 psi 8 116 psi 6bar 87 psi 4 0 0 5 C C2 1 2...
Page 42: ...42 www raider bg 0 C 6 7 8 50 1 2 Bar 9 2002 96 E...
Page 46: ...46 www raider bg 0 OFF 3 10 100...
Page 47: ...47 5 0 I 2BAR 29Psi 8 116 PSI 6bar 87 PSI 4 0 0 5 C C2 B1 B2...
Page 48: ...48 www raider bg 0 C 6 7 8 50 sedmichno Tova 1 2 9 2002 96...
Page 54: ...54 www raider bg...
Page 55: ...55...
Page 60: ...60 www raider bg 246 0700 44 155...
Page 62: ...62 1 5 2 bar Raider 18 Raider Industrial Raider Pro 12 Raider Power Tools Raider Garden Tools...
Page 63: ...63 112 115 112 1 2 1 2 3 113 1 2 3 2 114 4 5 114 1 113 1 2 2 3 115 4 115 1 2 1 3 1 1...
Page 69: ...69...
Page 70: ...70 www raider bg 45...
Page 73: ...73...
Page 77: ...77...