9
2. Set the pressure of 4-7 bar (60-100 psi) and airflow in accordance with the specifications.
3. CAUTION! Make sure air supply is clean and does not exceed 4-7 bar (60-100 psi) when
operating the switch. Too high pressure and dirty air will shorten the product life. Due to excessive
wear, machine parts can be dangerous and cause damage and / or injury.
4. Drain the air tank daily. Water in the air line will cause damage.
5. Clean the inlet air filter weekly.
6. Line pressure should be increased to compensate for unusually long air hoses (over 8
meters). The minimum diameter hose and equipment must have the same internal dimensions.
7. Keep the hose away from heat, oil and sharp edges. Check hoses for wear, and make sure
all connections are secure.
Lubrication
It is recommended to use Combined Regulator, Air Filter, Water Trap & Lubricator group (Fig4), since it
increases the life of the machine and keep the machine in continuous operation. Lubricator should be
regularly proveryavaa and filled with oil.
Proper setting of the lubricator is performed by placing a sheet of paper next to the exhaust ports and holding
the throttle open for about 30 seconds. Lubricator is properly set when the paper appeared bright spot of oil.
Excess oil should be avoided.
In case you need to store the machine for an extended period of time (overnight, weekends, etc.), it should
be thoroughly crushed. The machine must be turned on for about 30 seconds to ensure that the oil is evenly
distributed in The whole instrument. This tool should be stored in clean, dry environment.
It is very important that the machine is properly oiled, retains pipe lubricator complete and properly regulated.
If not lubricated properly it will not work properly and parts will wear prematurely.
Use a suitable lubricant in the lubricator. The lubricant must be low air flow or changing the type of airflow and
should be filled to the proper level. Use only recommended lubricants specifically designed for pneumatic
applications. Alternates may harm the rubber compounds in the machine, O-rings and other rubber parts.
IMPORTANT!
If not installed Combined Regulator, Air Filter, Water Trap & Lubricator group air system, pneumatic tools
should be lubricated at least once a day or after 2 hours with 2-6 drops of oil, depending on the work
environment directly through the hole in the hull.
INTRODUCTION:
The RD-AS01 pneumatic air stapler is made of high quality aluminum alloy, which strikes the right balance
between the strength and lightness of the product.
Precisely designed airflow economy system as well as lower noise level in operating mode.
LOAD
Attention! Always release the air stapler from the compressor mucus when reloading the cartridge. When
inserting the air stapler to the hose, point the perforating head to the ground. Keep your fingers away from
the trigger.