background image

RailKing FA-2 AA Diesel Set                                7

Your engine is equipped with a sound package of passenger station announcements that
you can play when you pull into a station.  Each sequence described below will play as
long as it is left on, randomly generating sounds, but be sure to allow approximately 30
seconds between the button pushes described below to allow the PSA sufficient time to
run through each sequence.

To cue the sound system to play the PSA, quickly but firmly tap the Bell button
once followed by 2 quick taps of the Horn button while the engine is moving. 
Tap the buttons quickly but allow approximately ½ second between each press.  

Press the Direction button once to stop the engine.  This will trigger the first
sequence of PSA. The reverse unit is temporarily disabled so that the train will
not move as you use the Direction button to trigger the sounds, and Proto-Sound
2.0 has disabled operator control over the Horn and Bell buttons until the full
PSA sequence is complete.

After waiting about 30 seconds for that sequence to run, press the Direction
button again to trigger the second sequence of PSA. 

After about 30 seconds, press the Direction button again to trigger the third PSA
sequence.  

Again, after allowing about 30 seconds for that sequence to run, press the
Direction button one more time to trigger the fourth and final PSA sequence. 
The PSA will continue, and within a few seconds, the engine and bell  will start
and move out on its own at the current throttle setting, in the same direction it
was traveling when you began the sequence.  Once the bell turns off, the operator 

+

Sound System Cued 

to Play Passenger 

Station Announcements (PSA)

Horn

Horn

Bell

Direction

1st

Sequence 

PSA

+

Direction

2nd

Sequence 

PSA

+

Direction

3rd

Sequence 

PSA

+

Direction

4th

Sequence 

PSA

=

Operator

Controls 

When Bell 

Turns Off

Passenger Station Announcements (PSA)

Summary of Contents for FA-2 AA

Page 1: ...tibility This engine will operate on any traditional O 31 Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transforme...

Page 2: ...oriesorstalledtrainsmayoverheat resulting in damage to your layout This train set is intended for indoor use Do not use if water is present Serious injury or fatalitymayresult l l l l Donotoperatetheh...

Page 3: ...low the lubrication points marked L in Fig 1 Do not over oil Use only a drop or two on each pivot point Lubricate Pick Up Rollers L Lubricate Wheel Axles L Figure 1 Lubrication Points on the Locomotiv...

Page 4: ...eed The engine will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly pr...

Page 5: ...ase the volume Proto Sound 2 0 Volume Adjustment Knob Figure 2 Manual Proto Sound 2 0 Volume Adjustment Placing The Engine On The Track Place the engine on the track then insert the reverse unit plug...

Page 6: ...ll you should tap the buttons very quickly with a second pause between button presses You may need to practice your timing to make this work smoothly Proto Sound 2 0 Operating Instructions Timing Char...

Page 7: ...ion button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Horn and Bell buttons until the full PSA sequence is complete After waiting about 30 seconds for that sequen...

Page 8: ...ve the throttle at a high voltage level once you have stopped the engine to run the PSA Otherwise the engine without PSA will begin vibrating on the track as its motors strain to move the train since...

Page 9: ...el for operation with speed control off to avoid high speed derailments When speed control is off the volume will drop to allow for better low voltage operation To turn speed control on and off put th...

Page 10: ...Direction Lock Two Horn Blasts Repeat to Return to Normal Condition indicates change is made To override the settings you currently have assigned to the engine and reset it to its factory defaults whi...

Page 11: ...ichever comes first Follow the greasing instructions below Note that in some tightly packed engines you may need to move internal components temporarily in order to access the gears 1 To access the ge...

Page 12: ...out the neoprene traction tires Periodically check the locomotive wheels and pickups for dirt and buildup which can cause poor electrical contact and traction and prematurely wear out the neoprene tra...

Page 13: ...r blade or small flathead screwdriver to pry away any remains 2 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 3 If y...

Page 14: ...and should last for up to five years The battery is a dry battery that should not leak or cause any damage to your engine Depending upon when your engine was built it may need to be charged right out...

Page 15: ...engine to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to replace the battery Available thro...

Page 16: ...l won t work on a separate bell button When I try to fire the coupler PSA starts The Proto Coupler won t let the engine uncouple on the fly When I press the whistle button the bell sounds Reverse the...

Page 17: ...ked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is s...

Page 18: ...istic as possible Proto Sound 2 0 disables the reversing unit whenever PSA is enabled This way the engine remains still at its stop as the operator cycles through the PSA sequences PSA is programmed t...

Page 19: ...dard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler...

Page 20: ...ch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including sound lights and smoke Proto Dispatch Operation Public Address like feature allows us...

Page 21: ...ght bulbs pick up rollers batteries smoke unit wicks and traction tires We wi ll repair or replace at our option the defective part without charge for the parts or labor if the item is returned to an...

Page 22: ...WARRICK CUSTOM HOBBIES PLANTATION 954 370 0708 info warrickcustomhobbies com www warrickcustomhobbies com FRANK S TRAINS HOBBIES INC OLDSMAR 813 855 1041 FTH allhobbies com www allhobbies com READY TO...

Page 23: ...246 mthdepot valstar net NASSAU HOBBY CENTER INC FREEPORT 516 378 9594 Charlienassau aol com KROSS HARDWARE WEST BABYLON 631 669 3069 t989 aol com CITY DEPOT INC NEW HAMPTON 845 374 3010 citydepot fro...

Page 24: ...INDEPOT MANASSAS 703 335 2216 NORGE STATION WIL LIAMSBURG 757 564 7623 norgetrains cs com NUTBUSH EXPRESS VICTORIA 804 696 1902 thenutbushexp meckcom net TOY TRAIN CENTER RICHMOND 804 288 4475 T S G H...

Reviews: