Positioning the square 

 

 

BEFORE PERFORMING ANY OPERATION, MAKE SURE THAT THE MACHINE IS 
UNPLUGGED.

 

 

 

ATTENTION: CHECK THAT THE SQUARE (A) IS RESTING ON THE BLOCK (H) AND THAT 
THE LEVER (C) IS LOCKED.

 

 

NORMAL CUTS 

 

    

 

 

 

Set the tile on the square (A) and on the rest (B). 

 

 

NOTE: TO ENSURE A PERFECTLY 
SQUARE CUT, REST THE TILE PRE-
CISELY AGAINST THE SQUARE (A). 

 

 

Position the indicator on triangle (G) at the 
requested measure and lock it with the lever (D). 

 

 

NOTE: IF THE CUT IS NOT PARALLEL:
- Make sure the square (A) and the rest 
(B) are aligned; 
- Adjust the position of the square (A) 
by turning the adjustment screw (F).
 

 
DIAGONAL CUTS 

 

    

 

 

 

Loosen the knob (C) and position the square at 
45°. 

 

Loosen the lever (D) and position the indicator 
(G) on the triangle (E), namely on the 
DIAGONAL tile measurement. Tighten levers (C
and (D). 
Keeping the diamond disk above the surface of 
the tile, run the motor assembly and adjust its 
position so that, at the beginning and end of the 
cut, the diamond disk lines up with the corners of 
the tile. 

 

Reposition the triangle in the correct position and 
tighten the lever (D). 

 
 
 
 
 
 

 

NOTE: WHEN CUTTING AT ANGLES OTHER THAN 90° AND 45°, TRACE THE CUTTING 
LINE ON THE TILE. 
WITH THE MOTOR OFF, PLACE THE TILE ON THE MACHINE TABLE. 
LET THE DISK RUN OVER THE TILE AND MAKE SURE THE CUTTING LINE CORRE-
SPONDS TO THE LINE PREVIOUSLY TRACED ON THE TILE. MOVE THE SQUARE 
AGAINST THE TILE EDGE AND LOCK IT IN PLACE WITH THE LEVER (C).
 

 

 

 

 

F

IG

.

 

 

 

 

 

F

IG

.

 

 

D

E

A

F

C

E

H

Summary of Contents for PIKUS 105

Page 1: ...GB...

Page 2: ......

Page 3: ...ta 4 Technical data for motors 4 The machine units 5 Workstation 5 Safety devices 5 Noise 6 Safety Precautions 6 Transport of the package 6 Manual handling 6 Electrical Power Supply 7 Checks before us...

Page 4: ...URAL STONE Limitations The PIKUS 105 105DL 75 75DL saws are designed to be used only with the disks described above and must be water cooled Never use the machine with disks for wood working machines...

Page 5: ...correct working position While the machine is running never reach into the cutting zone C which is the gap between the two half plates During operation the operator must be standing on the front side...

Page 6: ...dB A To reduce the risk stemming from exposure use appropriate ear protection Also see Italian Law 277 91 for more specific indications Always wear goggles and protective gloves If the machine cuts ou...

Page 7: ...ed in the table TRANSFORMER 230V 50Hz 1 1kW 230V 60Hz 1 1kW 115V 50Hz 1 kW 115V 60Hz 1 kW DIFFERENTIAL 8 5A Id 20mA 8 5A Id 20mA 17A Id 20mA 17A Id 20mA ATTENTION ALWAYS REMEMBER TO PERIODICALLY CHECK...

Page 8: ...th BEFORE PERFORMING ANY OPERATION MAKE SURE THAT THE MACHINE IS UNPLUGGED The PIKUS machine can be used as follows With the motor assembly locked in place at the desired cutting depth tightening the...

Page 9: ...UTS Loosen the knob C and position the square at 45 Loosen the lever D and position the indicator G on the triangle E namely on the DIAGONAL tile measurement Tighten levers C and D Keeping the diamond...

Page 10: ...ait until the cooling water reaches the diamond disk Proceed with cutting slowly bringing the diamond disk up against the material to be cut Continue cutting keeping the forward speed steady Towards t...

Page 11: ...OND DISK DOES NOT TOUCH ANY PARTS OF THE MACHINE OR THE MA TERIAL TO BE ROUNDED OFF Position the tile to be rounded off with the glazed side facing upwards on the work surface and make certain that it...

Page 12: ...REGULARLY GREASE THE CHUCK BEARINGS IN THE POINT OF CONTACT WITH THE DISK HOLDER FLANGE CLEANING THE TANK Remove the two half plates Empty the water from the tank by removing the plug A at the bottom...

Page 13: ...nd on the disk guard To ensure that the disk is firmly secured in place tap on the shaft of the 22 mm Allen wrench with a hammer Refit the disk guard Manually rotate the disk to check that it has been...

Page 14: ...o the pump Fasten the pump A in place by tightening the wing nut B Replacing the starter BEFORE PERFORMING ANY OPERA TION MAKE SURE THAT THE MA CHINE IS UNPLUGGED Open the terminal block cover of the...

Page 15: ...HINE OR PARTS ARE TO BE DEMOLISHED FOLLOW THE INDICATIONS OUTLINED IN THE CURRENT LEGISLATION SWITCH HOLDER ABS ABS MACHINE BODY STEEL AC ALUMINIUM AL POLYAMIDE PA DISK GUARD SLIDE BAR COLUMN SQUARES...

Page 16: ...PIKUS 105 105DL PIKUS 75 75DL ENGLISH 16...

Page 17: ...423AS RON LOCKING PIN 18 263FE07D MOBILE DISK GUARD 19 114RE09D 114RE10D GUIDE PIKUS 75 GUIDE PIKUS 105 20 156NL09D 156NL10D AL GRID PIKUS 75 AL GRID PIKUS 105 21 158GB02D RING NUT 75 POS CODE PART N...

Page 18: ...SINGLE PHASE 230V 50Hz 1 1kW 8 5A 2800 min 1 MOTOR CLASS F D SINGLE PHASE 230V 60Hz 1 1kW 8 5A 3360 min 1 MOTOR CLASS F D SINGLE PHASE 115V 50Hz 1kW 17A 2800 min 1 MOTOR CLASS F D SINGLE PHASE 115V 60...

Page 19: ......

Page 20: ...PIKUS PIKUS Date of manufacture Serial n RAIMONDI S p A MODENA 2003 developed by TECNO DINAMICA S n c...

Reviews: