9
ESP-LXIVM S
eries Controllers
IVM-OUT (
Output De
vice)
IVM-OUT 2-
Wire control devic
es can be used
to control valv
es with DC la
tching solenoids
.
AL
Connect the r
ed and black wir
es on the IVM
-
OUT to the 2-
Wire Path.
BL
Connect the r
ed/whit
e striped wir
e on the
IVM-OUT t
o the DC la
tching solenoid r
ed
wire.
CL
Connect the black/whit
e striped wir
e on the
IVM-OUT t
o the DC la
tching solenoid black
wire.
DL
For futur
e troubleshooting or modifica
tions,
it is recommended t
o leave an additional 3
feet (1 meter)
of 2-Wire cable
stored in each
valve box loca
tion.
L
B
NOTE: Make sur
e that the DC la
tching sole
-
noid is c
ompatible with non R
ain Bird valves
.
Contact the v
alve manufac
turer for mor
e
information.
NOTICE
Maximum c
ombined wir
e length bet
ween IVM
-
OUT and its load (e
.g. Solenoid) shall be 48 in.
This includes pr
e-installed IVM
-OUT wir
e (24 in.)
and solenoid wir
es (22 in.).
Use only
WC20 splic
e kits for all wir
ing connec
-
tions to the 2-
Wire Path. I
mproper wir
ing can
cause ser
ious damage t
o your controller or ir
ri-
gation sy
stem.
Non-Rain Bir
d
valve with DC
Latching S
olenoid
Valve
Box
2-Wire
Cable
Allow 3 ft. (1 m)
Extra Cable
Length
A
D
IVM-OUT
C
B
Typical IVM-
OUT Wiring
ESP-LXIVM Series Controllers
Field Device Installation Guide
690715-01_18NO19_LX-IVM field device install guide EN.indd 1
690715-01_18NO19_LX-IVM field device install guide EN.indd 1
1/23/2020 5:41:15 AM
1/23/2020 5:41:15 AM