Installation
ENG
ESP-Me Controller
8
Wiring Connections
Connect Valves
A
Route all field wires through the opening at the
bottom or back of the unit. Attach conduit if
desired, as shown.
c
c
WARNING:
Do not route the valve wires through
the same opening as the power wiring.
B
Connect one wire from each valve to the terminal
on the base module or Station Module that
corresponds to the desired station number (1-22).
C
Connect a field common wire (C) to the common
terminal (C) on the base module. Then connect
the remaining wire from each valve to the field
common wire, as shown.
D
To perform a Valve Test, connect the common wire
to the “COM” terminal and the power wire to the “VT”
terminal. This will immediately turn the valve “ON” .
Connect Master Valve (optional)
E
Connect a wire from the master valve to the master
valve terminal (MV) on the base module. Then
connect the remaining wire from the master valve
to the field common wire, as shown.
A
B
MASTER
VALVE
C
MV
1
2
SENS
E
C
Summary of Contents for ESP-Me
Page 139: ...This page intentionally left blank...