background image

4

5

B

B

A

11

B

B

A

12

13

COM

1 2 3

4 5

6

B

A

6

7

B

A

C

8

B

A

9

B

A

3

A

B

C

Operating Ranges

   

 

  

 

   

 

  

   

 

 

  

   

 

  Flow

2

 

 

 

  

  

   

   

  

  

   

   

 

  

  

  Pressure  

 

  

  

   

 

 

 

  

 

 

   

GB

JTV/JTVF male x male (MM) and male x barb (MB) are not recommended for flows exceeding 30 GPM (6,8 m

3

/h or 1,9 I/s). 

For flows below 3 GPM (0,75 m

3

/h or 0,21 I/s), or any Landscape Drip application, use RBY-100-200MX filter installed 

upstream.

Loosen solendoid 

1

2

 turn and then tighten the solenoid completely (

1

4

 turn beyond hand 

tight). Use the solenoid handle, which is specifically designed to shut the valve off completely 
and keep it from “weeping.” Also tighten the bleed screw and bonnet.  

Use the external bleed screw to flush the valve. If performance does not improve,
turn off water. Unscrew bonnet and remove. Remove diaphragm and clean it in clear water. 
Reinstall diaphragm and bonnet. If necessary, replace the diaphragm with kit number 
231771.

Check water source, controller power, and flow control to make sure they are open.  

Turn off water. Unscrew bonnet and remove. Inspect body for debris. If filter is missing from 
diaphragm, replace diaphragm with kit number 231771.

Turn off water. Remove solenoid and replace with a known working solenoid. If the valve still 
won’t open, replace the solenoid.

Check system water pressure. If pressure is greater than 80 psi (5,5 bars), install a
pressure regulator on the line before the valve to reduce water pressure.

Check to ensure the yellow o-ring inside the union connector is in place.  If lost, replace with 
part #231771.  If necessary, tighten connectors further.

Check for blocked dump port (especially slip 
x slip). Remove bonnet. Remove diaphragm. 
Insert a probe (flag marker wire or paper 
clip) as shown.

 

NOTE

:  During winter shutdown, drain the system to protect JTV valves  

 from  freezing. Failure to properly drain lines may damage the  

 

 valves. Be sure to comply with all local guidelines.

100-JTV, 100-JTVF, 100-JTV-MB

1

, 100-JTV-SS, 100-JTVF-SS  

1 to 30 GPM  

(0,23 to 6,82 m

3

/h;  

0,06 to 1,89 l/s)

15 - 15O psi

(1,0 - 10,3 bars)

4. 

(Threaded non-union models only)

  

To make a watertight seal, wrap 1

1

2

  to 2 turns of 

Teflon tape around the threads on two male x slip 
adapters (A) or on the male threads of the valve  
(B; MM and MB models) 

 

(Threaded union models only)

 

To make a watertight seal, use male threaded adapters 
with a smooth, flat face for the o-ring to seal against.  

 

CAUTION

:  Do not use teflon tape for union valve  

models.

  

Before Installation

1.  Make sure you have sufficient water supply, pressure, 

and flow. Connect pipes to primary water source.

2.  Install master valves, pressure regulators, and backflow 

preventers as needed. For system design information, 

refer to the 

Rain Bird lrrigation Design Guide

. Refer to 

local building codes for additional requirements.

3.   Flush the system thoroughly until the water from the  

submain runs clear.

Connect Adapters to Valve

5.   Screw the adapters into the valve water ports and hand 

tighten.

  Carefully tighten the adapters one to two additional 

turns past hand-tight.

 

CAUTION

:   Do not over-tighten the adapters. You may  

damage the valve or block the exit ports.

Connect Valve to Pipes

7.  Carefully apply a small amount of solvent cement to the 

inside of the adapter (A, threaded connector) or valve 
inlet port (B, slip connector). Apply a small amount of 
cement to the outside of the water supply pipe. Then 
attach the valve to the pipe. The valve solenoid 

MUST 

be on the downstream side (C).

 

CAUTION

:   Use only a small amount of solvent  

cement. Excess cement can damage the valve 
internally.

8.  Cement the lateral pipe to the adapter (A, threaded 

connector) or valve outlet port (B, slip connector), as 
described in step 7.

9.  To attach an MB model valve to low-density 

polyethylene pipe, cut the pipe square and clean. Slip 
one or two clamps over the poly pipe.

  If necessary, carefully heat the poly pipe for easier 

installation. Slip the poly pipe completely over the barb 
(A). Then clamp (B) the pipe securely to the barb for a 
leak-proof seal.

Connect Valve Wires

10.  Select a wire gauge that meets electrical specifications. 

Multi-strand, direct-burial wire is recommended. Refer 
to local building codes for additional requirements.

11. Use a watertight connector to connect one lead on each 

valve to a common wire (A). Either lead may be used. 
All valves on the same controller can share the same 
common wire.

  Use a watertight connector to connect the second lead 

on each valve to a power wire (B). Each power wire 
must be run separately to the controller.

12. Connect the shared common wire (A) to the common 

terminal on the controller. Connect one power wire from 
each valve (B) to a station terminal on the controller.

Operate Valve Manually

13  To open the internal bleed, turn the solenoid handle (A) 

counterclockwise 

1

4

 to 

1

2

 turn. Be sure to re-tighten the 

solenoid completely. Always use the solenoid handle, 
which is designed to shut the valve off completely and 
keep it from “weeping.”

  To reduce flow (JTVF models only), turn the flow 

control stem (B) clockwise. Use your fingers or a slot-

head screwdriver. To increase flow, turn the stem 
counterclockwise.

   To open the external bleed, turn the bleed screw (C) 

counterclockwise two turns. 

Use the external bleed to 

flush the valve when you first start the system

. Turn the 

screw clockwise to close it.

GB

4a

4b

5

7

8

9

11

1

6

1

JTV with Bonnet and Diaphragm Removed

Poke wire through this slot 

to clear adhesive.

Troubleshooting

  

Symptom 

   Solution

  Valve won’t shut off    
  completely.  

 

  

 

 

 

  Sprinklers “weep.”  

 

 
 

  Valve won’t open. 

  Valve slams on / off

  (water hammer). 

  Connectors on Union 
  Valve are leaking

  Valve opens manually  
  but not electrically

Summary of Contents for JTV Series

Page 1: ...Provence Cedex 3 France Phone 33 442 24 44 61 Fax 33 442 24 24 72 Rain Bird Mexico S de R L de C V Calzada Juan Gil Preciado 2450 Nava 15A Parque Ind Ecopark Colonia El Tigre CP45100 Zapopan Jalisco...

Page 2: ...lding codes for additional requirements 3 Flush the system thoroughly until the water from the submain runs clear Connect Adapters to Valve 5 Screw the adapters into the valve water ports and hand tig...

Page 3: ...d un ou deux tours suppl mentaires avec pr caution ATTENTION Ne forcez pas trop sur les filetages Vous pourriez endommager la vanne ou la bloquer Montage des vannes sur les tuyaux mod les raccords co...

Page 4: ...ICHT Verwenden Sie kein Teflonband f r Anschlussventile 55 Schrauben Sie die Anschluss Fittings in den Ventil Wasseranschluss und drehen Sie sie mit der Hand fest Dann schrauben Sie sie nochmals ein o...

Page 5: ...e poich si potrebbe danneggiare la valvola o bloccare l uscita Collegamento delle Valvole alle Tubazioni 7 Applicare con attenzione una piccola quantit di sigillante all interno del raccordo A raccord...

Page 6: ...a contra la que pueda trabajar bien la junta t rica PRECAUCI N No utilice cinta de tefl n para los modelos de v lvula con uni n de rosca de giro loco Enrosque los adaptadores en los orificios de entra...

Page 7: ...om een waterdichte afdichting te maken Alleen modellen met koppeling Gebruik buitendraadverloopstukken met een glad vlak oppervlak voor de o ring om tegen af te dichten om een waterdichte afdichting...

Page 8: ...de uni o Para selar prova de gua usar adaptadores com rosca macho com uma face polida e plana voltada para o o ring para selarem um contra o outro CUIDADO N o usar fita Teflon para modelos de rosca d...

Page 9: ...4a 4b 5 3 6 11 13 12...

Page 10: ...2 tur Teflon band sar n Yaln z di li ba lant l modeller Su s zd rmamas i in kapanacak olan o bilezik i in p r zs z ve d z bir y zeyi bulunan erkek di li rakorlar kullan n D KKAT Ba lant l vana modelle...

Reviews: