background image

1

INSTALLATION & OPERATING INSTRUCTIONS

1. Flush main line thoroughly before installing valves.

2. Install valve onto main line.  Ensure inlet side is connected

to main line and outlet side is connected to lateral line.  Note
arrow on valve indicating direction of water flow.  Solenoid
should be on the downstream side of the valve.

3. NOTE: Valve is configured for globe installation. For angle

installation, remove inlet plug then thread into globe inlet.
We recommend using a closed end wrench to avoid strip-
ping any molded parts.

4. Use two wraps “Teflon Tape” along the full length of the inlet

and outlet pipe threads. 

Do not use pipe thread or pipe

dope compound.

Thread inlet pipe and fitting into the inlet

port of the valve and hand tighten.  Thread outlet pipe and
fitting into the outlet port of the valve and hand tighten.  Do
not exceed two turns beyond hand tight.

5. Connect one solenoid wire to the controller common wire

and the other to the controller power wire.  Use only water-
tight wire connectors, like RAIN BIRD ST-03.

6. After installing valves, slowly open water supply at point of

connection.  Valves may discharge water momentarily, then
shut off.

7. To activate the valve using the 

internal

manual bleed fea-

ture, turn the solenoid handle counter clockwise 

1

4

to 

3

4

turn

or until you hear water flowing through the valve.  To close
valve, turn the solenoid handle clockwise 

1

4

to 

3

4

turn and

wait a moment for the valve to close.  Only hand tighten the
solenoid to close the valve.

8. For automatic valve operation, turn on the controller that

has been wired to the valve according to the controller oper-
ating instructions, as controllers operate differently.

9. Use the flow control handle to adjust the amount of water

flowing through the valve.  Counter clockwise turns increase

Summary of Contents for PGA

Page 1: ...PGA...

Page 2: ...of the valve and hand tighten Do not exceed two turns beyond hand tight 5 Connect one solenoid wire to the controller common wire and the other to the controller power wire Use only water tight wire c...

Page 3: ...tionally trying to limit the flow is to turn the flow control stem from the full up position clockwise until resistance is felt on the flow control stem handle 10 If necessary install Rain Bird s pres...

Page 4: ...align ment of the diaphragm with the valve body and positioning tabs Inspect the diaphragm for nicks or damage then realign or replace diaphragm as necessary Dirt is interfering with proper solenoid...

Page 5: ...Turn off the water supply and remove the bonnet Inspect the diaphragm filter screen located on the bottom of the diaphragm Remove debris rinse screen in clean water and return diaphragm and bonnet to...

Page 6: ...ontroller not supplying power to valve Check the controller for output power to the valve If no power is detected at controller then service controller Check power input at the solenoid of the valve I...

Page 7: ...om the full up position clockwise until resis tance is felt on the flow control stem handle Then turn the flow control stem handle counter clockwise one turn as the valve will operate more effectively...

Page 8: ...uth Africa P O Box 1260 Strubens Valley 1735 South Africa Phone 27 11 958 1930 Fax 27 11 958 1931 Rain Bird in Southeast Asia C 212 Marina Bay Asiaworld Aguinaldo Highway Paranaque Metro Manila 1703 P...

Reviews: