WS-PRO2 Weather Station Manual
GT
27176
Page 61 of 61
•
Make sure the battery voltage is between 9.6 and 16 VDC.
•
Verify sensors are plugged into the correct bulkhead
connector and locking ring is securely in place (see Figure
17). Check connectors for any corrosion on pins.
•
If Smart Weather is used to create the station program
double check the wiring diagram to see if it matches the
physical wiring on the bulkhead connectors on the back of
the enclosure.
Unreasonable Results Displayed in an Input Location
•
Inspect the sensor for damage and/or contamination.
•
Make sure the sensor is plugged into the correct bulkhead
connector on the back of the enclosure.
6999 or 99999 Stored in Final Storage (or Storage Module)
•
Something is wrong with the datalogger and/or sensor(s).
Summary of Contents for WS-PRO2
Page 22: ...WS PRO2 Weather Station Manual GT 27176 Page 22 of 61 Figure 13...
Page 24: ...WS PRO2 Weather Station Manual GT 27176 Page 24 of 61 Figure 14...
Page 26: ...WS PRO2 Weather Station Manual GT 27176 Page 26 of 61 Figure 15...
Page 28: ...WS PRO2 Weather Station Manual GT 27176 Page 28 of 61 Figure 17...
Page 32: ...WS PRO2 Weather Station Manual GT 27176 Page 32 of 61 Figure 20...
Page 33: ...WS PRO2 Weather Station Manual GT 27176 Page 33 of 61 Figure 21...
Page 46: ...WS PRO2 Weather Station Manual GT 27176 Page 46 of 61 Figure 32...