Page 15
Behind the lower panel of the controller, the station numbers are labeled next to each connector.
Simply match the station wire to the appropriate field wire.
WARNING: ALWAYS TURN-OFF POWER before changing or modifying field, senor
or power wiring within the controller. Dangerous voltage and current exist
within the controller which may damage the controller if improperly
connected or shorted.
NOTE:
The controller's COMMON wire is WHITE and the MASTER
VALVE/PUMP is BLACK.
If it becomes necessary to remove the Quick Connector blocks from the printed circuit board, hold
the plastic assembly and pull down-ward gently, but with firm pressure.
NOTE:
When reattaching the Quick Connector, be sure that the lip at the top of the
plastic connector is facing you as you push the connector onto the pins.
Additionally, be sure to match the Quick Connector blocks with the
corresponding color as labeled on the bottom edge of the printed circuit
board.
3.2.1 Master Valve and Pump Wiring Options
The RME EAGLE provides a variety of control options when selecting a Master Valve and Pump.
Because the Master Valve and Pump can be assigned to any program, and the Master Valve can be
either a Normally Open or a Normally Closed valve configuration, virtually any system
configuration can be accommodated.
For example, drip irrigation programs, which don’t use a pump, may be setup in one or more of the
available programs. Irrigation systems which use large rotors may be programmed to use a pump.
The following table summarizes the configuration options, which are available. The installation
diagrams required to achieve these options are described in greater detail in the following
paragraphs and the corresponding SETUP function. For detailed information on SETUP functions,
please refer to 6.0 SETUP KEY OPERATIONS.