After completing the physical installation of the flow sensor, make the necessary wiring connection
from the flow sensor to the RME EAGLE controller as follows:
1.
TURN THE POWER OFF AT THE CONTROLLER.
2.
At the Flow Sensor:
•
Connect the
BLACK
wire of the Flow Sensor to the
BLACK
wire of the “
EV-
CAB-SEN
” sensor cable.
•
Connect the
WHITE
wire of the Flow Sensor to the
WHITE
wire of the
“EV-CAB-
SEN
” sensor cable.
NOTE: * Use the weatherproof wire nut connectors provided with the Flow
Sensor to make the splice.
3. At the RME EAGLE controller:
•
Connect the
BLACK
wire of
“EV-CAB-SEN
” cable to Pin 4 (
FLOW
-) of the RME
EAGLE Controller.
•
Connect
WHITE
wire of
“EV-CAB-SEN
” to Pin 3 (
FLOW
+) of the RME EAGLE
Controller.
4. Turn
POWER ON
at the Controller.
5. Using the SETUP key, enable the Flow Sensor and select the pipe size for the Flow Sensor
installed.
3.2.3
Sensor Wiring
The RME EAGLE controller supports most modern 2-wire Rain or Moisture sensor configurations.
The 2 wire sensors are connected to pins 1 and 2 on the sensor connector, as depicted in Figure 11 –
Sensor Interface Electrical Connections.