Chapter 6 Setup Key Operations
Page 85
NOTE:
If you have selected a Normally Closed Master Valve, the Master Valve will
also come on. If Station 7 is in any program which has a Pump assigned to
it, then the Pump (Station 1) will also come on.
Display will indicate:
The value on the left is the measured or (nominal) flow and the value on the right is a previously
established limit (both in GPM). The flow display will update once every 10 seconds.
You can now watch the display until you see that the flow has reached a stable value and you want
to use that value (adjusted up by the flow percentage) for your limit.
Suppose the stable value is 45 GPM, then your display will be
Press:
Display will indicate:
The new limit will be 45 adjusted up by 30% or 58 GPM.
EXAMPLE:
Turn on Station 7 and monitor its flow without changing its upper flow limit.
Continue
to
Press:
Until display indicates:
Press:
Display will indicate:
Press:
Station 7 will begin watering and its flow will be displayed. The Master Valve and/or Pump may
also be on, depending on previously established conditions.
0 5 2 2 00
PROGRAM
0 4 5 2 00
PROGRAM
L I M I T S
PROGRAM
7 - 2 00
PROGRAM
SETUP
L I M I T S
PROGRAM
ENTER
7
SAT
MANUAL
ENTER