11
that your spa is plugged into. Your 230 volt spa’s subpanel is rain tight when
installed correctly with the door closed.
Leave access to the equipment compartment for periodic spa care and maintenance.
The spa should be placed a minimum of 3 feet from all structures to allow
access to all sides for servicing and repair. If the spa cannot be serviced
and repaired due to un-accessibility of sides, it is the customer’s obligation
to have tub drained, moved, and placed in an accessible site.
Start –Up Instructions
Always refill spa through one filter housing to purge any trapped air from pump intakes.
Failure to do so may cause air to be trapped in wither pump #1 or the circulation pumps
intake creating an (air lock), preventing either pump from circulating water. Insure both
shutoff valves are fully open. Re-install filter cartridge, filter housing assembly and lid.
Make sure filter cartridge is clean before installing.
Filter Housing Assembly
Remove filter lid and rotate top filter housing counterclockwise and remove assembly.
Remove filter cartridge upward, and inspect element for cleanliness. The proper way to fill
your spa using a common garden hose is with cartridge element removed. Once spa is filled
with water 1” below pillows, re
-install filter cartridge and housing assembly locking it back
in place replacing filter lid.
Fiberoptic Lighting
All replacement lighting must be provided by Raindance Spas or J & J Electronics.
Warranty will be void with any other replacement.
Draining and Refilling Spa
Draining:
Turn the power off to the system by turning off the GFCI breaker. Remove the drain cap
from the drain valve and attach a garden hose to the drain bib. Turn the drain bib
counterclockwise to open and allow water to drain. Close drain bib by gently turning
clockwise (carefully and do not over-tighten) and install drain bib cap.