tion device (fuse) in the positive lead. This pump requires a 10 amp
fuse (12V) or a 5 amp fuse (24V).
15. The pump circuit should not include any other electrical loads.
16. As the water supply pump is non-essential, reference the wire chart
under the electrical information. Be sure to have the correct wire
sizing for the length of wire you are using.
17. After installation, check the voltage at the pump motor. Voltage
should be checked when pump is operating. Full voltage must be
available at the pump motor at all times.
Notes
:
1. Flexible potable water hose or PEX tubing is recommended instead
of rigid piping at pump. If using rigid piping, provide a short length of
hose between pipe and the pump to avoid noise and vibration.
2.
Metal fittings are not recommended. When possible, use the provid
-
ed plastic fittings.
3. Do not adjust the bypass without the help of a technician.
4. Lack of sanitizing and maintenance is one of the main reasons of
under performance of the pump. Please perform maintenance and
winterize the pump at appropriate times, especially before and after
a period of storage.
About the Bypass
Please consult a professional technician in the case that the bypass
needs adjustment. Improper adjustment of the bypass may damage the
pump.
The bypass comes preset for optimal operation of the pump. If your
application calls for a different setting for the bypass, you may change it
yourself. Carefully tighten the screw to increase or loosen the screw to
decrease the minimum operational pressure of the bypass.
CAUTION
Please follow the instruction manual to install the product. Any action
outside what is recommended in this manual may bring damage to the
pump. Any inappropriate installation or operation that causes the pump
damage is not covered by warranty.