3

tion device (fuse) in the positive lead. This pump requires a 10 amp 

fuse (12V) or a 5 amp fuse (24V).

15.  The pump circuit should not include any other electrical loads.
16.  As the water supply pump is non-essential, reference the wire chart 

under the electrical information. Be sure to have the correct wire 
sizing for the length of wire you are using.

17.  After installation, check the voltage at the pump motor. Voltage 

should be checked when pump is operating. Full voltage must be 
available at the pump motor at all times. 

Notes

:

1.  Flexible potable water hose or PEX tubing is recommended instead 

of rigid piping at pump. If using rigid piping, provide a short length of 
hose between pipe and the pump to avoid noise and vibration.

2. 

Metal fittings are not recommended. When possible, use the provid

-

ed plastic fittings. 

3.  Do not adjust the bypass without the help of a technician.
4.  Lack of sanitizing and maintenance is one of the main reasons of 

under performance of the pump. Please perform maintenance and 
winterize the pump at appropriate times, especially before and after 
a period of storage.

About the Bypass

Please consult a professional technician in the case that the bypass 
needs adjustment. Improper adjustment of the bypass may damage the 
pump.
The bypass comes preset for optimal operation of the pump. If your 

application calls for a different setting for the bypass, you may change it 

yourself. Carefully tighten the screw to increase or loosen the screw to 
decrease the minimum operational pressure of the bypass.

 

CAUTION

Please follow the instruction manual to install the product. Any action 
outside what is recommended in this manual may bring damage to the 
pump. Any inappropriate installation or operation that causes the pump 
damage is not covered by warranty.

Summary of Contents for 36667

Page 1: ...12V 24V Diaphragm Pumps USER MANUAL...

Page 2: ...It is the installer s responsibility to read understand and comply with these instructions...

Page 3: ...tch 1 FEATURES 4 chamber diaphragm pump Continuous duty Bypass reduces cycling Self priming Quiet operation Ignition protected Run dry capable for normal workloads Automatic controlled by pres sure sw...

Page 4: ...ts no smaller than 10 mm 4 Plumb the system using high pressure 2 x pump rating braided flexible tubing to minimize vibration noise 5 Do not apply inlet pressure in excess of 30 PSI In general try to...

Page 5: ...rovid ed plastic fittings 3 Do not adjust the bypass without the help of a technician 4 Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump Please perform ma...

Page 6: ...Leads 16 AWG 9 4 in 24 cm long with 2 pin connec tor leads Duty Cycle Intermittent Max Amp Draw 7 00A 12V 3 37A 24V Fuse 10A 12V 5A 24V Standard Pump Configuration Part Numbers Voltage Open Flow Contr...

Page 7: ...WG 0 20 16 AWG 20 30 14 AWG 30 50 12 AWG 50 65 10 AWG 7 REPAIR KITS Key Description Quantity A Pump Head Assembly 1 B Valve Assembly 1 C Diaphragm Assembly 1 D Motor Assembly 1 1 Pressure Switch 1 2 D...

Page 8: ...take or discharge line Air leak in the intake line Punctured pump diaphragm Initial amp supply is not enough to sufficiently start the motor Debris clogged in the valves Crack in pump housing Motor Fa...

Page 9: ...letely mark the screw in relation to the bypass housing for reference as to number of turns start screwing the set screw clockwise 10 to 11 turns See Picture 2 Note 3 This will increase the maximum by...

Page 10: ...8...