Use the following process to adjust shut-off and bypass pressures

 

*Remove the pressure adjustment screw completely, mark the screw in 

relation to the switch housing for reference as to number of “turns”, start 

screwing the set screw clockwise “9 to 9½ turns”, as the 3 in picture 2 

indicates. This will increase the pressure to shut-off at approximately 60 

PSI.

*Remove the bypass adjustment screw completely, mark the screw in 

relation to the bypass housing for reference as to number of “turns”, start 

screwing the set screw clockwise “10½ to 11 turns” (See Picture 2, Note 

3.). This will increase the maximum bypass pressure to approximately 67 
PSI.

*How to verify the shut-off and bypass pressures

After adjusting the screw, slowly close the valve until shutoff. The pres

-

sure gauge pointer will indicate shut-off/bypass pressure.

3.

Picture 1

water tank

pump

valve

outlet

pressure 

gauge

Picture 2

1. pressure adjustment

set screw type; 5/64 (2mm) 
allen key

2. bypass adjustment

set screw type; 5/64 (2mm) 
allen key

Summary of Contents for 36667

Page 1: ...12V 24V Diaphragm Pumps USER MANUAL...

Page 2: ...It is the installer s responsibility to read understand and comply with these instructions...

Page 3: ...tch 1 FEATURES 4 chamber diaphragm pump Continuous duty Bypass reduces cycling Self priming Quiet operation Ignition protected Run dry capable for normal workloads Automatic controlled by pres sure sw...

Page 4: ...ts no smaller than 10 mm 4 Plumb the system using high pressure 2 x pump rating braided flexible tubing to minimize vibration noise 5 Do not apply inlet pressure in excess of 30 PSI In general try to...

Page 5: ...rovid ed plastic fittings 3 Do not adjust the bypass without the help of a technician 4 Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump Please perform ma...

Page 6: ...Leads 16 AWG 9 4 in 24 cm long with 2 pin connec tor leads Duty Cycle Intermittent Max Amp Draw 7 00A 12V 3 37A 24V Fuse 10A 12V 5A 24V Standard Pump Configuration Part Numbers Voltage Open Flow Contr...

Page 7: ...WG 0 20 16 AWG 20 30 14 AWG 30 50 12 AWG 50 65 10 AWG 7 REPAIR KITS Key Description Quantity A Pump Head Assembly 1 B Valve Assembly 1 C Diaphragm Assembly 1 D Motor Assembly 1 1 Pressure Switch 1 2 D...

Page 8: ...take or discharge line Air leak in the intake line Punctured pump diaphragm Initial amp supply is not enough to sufficiently start the motor Debris clogged in the valves Crack in pump housing Motor Fa...

Page 9: ...letely mark the screw in relation to the bypass housing for reference as to number of turns start screwing the set screw clockwise 10 to 11 turns See Picture 2 Note 3 This will increase the maximum by...

Page 10: ...8...

Page 11: ...9...

Page 12: ...RainHarvest Systems RainHarvest com 800 654 9283 092121...

Reviews: