15
Ro-Trak not functioning? Check for these problems.
1.
Is the PTO engaged?
2.
Is a 12 volt battery properly connected?
3.
Is sensor at the back of machine plugged in (page 14)?
4.
Check oil level.
5.
Check for any damaged hoses or wires.
6.
Check for loose wire connections /plugs.
7.
Is sensor lifted 3” or more? (Sensor has transport cut off switch).
8.
Do the indicator lights in the sensor micro switches light up (page 14)?
9.
Do the indicator lights in the wire plugs light-up (see below)?
10.
If indicator lights light-up and Ro-trak doesn’t function, push in both
silver pins on solenoid spools several times using a screwdriver.
11.
If indicator lights do not light up, remove lid of grey box on back of
sensor and check for loose wires.
12.
Call Rain-Flo at 717-445-3000.
Hyd. Oil Level
Solenoid Valve
Oil Level
1. Periodically check oil level. Low oil level may cause air
to come into the system and effect Ro-trak performance.
2. Change oil and filter every 200 hours or 3 years (ISO 46 Hyd. Oil).
3. Check for any damaged hoses or electric wires.
Auto Ro-Trak Maintenance
Valve
Spools
Silver Tip
Indicator
Lights
Valve
Spool
Silver Tip