background image

Your commitment to saving water through the use of harvested rainwater is commendable, and is a very 

important step towards increasing your personal water sustainability.

To match your commitment to saving water we have committed to ensuring that the pumps and pump 

controllers we offer are of the highest quality available. 

P

lease Note:

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety.

 

Children should be 

supervised to ensure that they do not play with the appliance.

Mainly applicable for pumping industrial fluids, such as mineral

 

water, soft 

water, pure water, clean oil and circulation and boosting of

 

other weak 

chemical-industrial mediums.

Rainwater harvesting systems

Greywater systems

Water treatment processes

Industrial cleaners and dishwashers

Water boosting applications

Heating and cooling for industrial processes

Air-conditioning systems

Air freshening, heater device (soft water)

Water supply and boosting (drinking water, light chlorine water)

Fertilization/metering syste

m

Liquid temperature: 0℃ ~ 70℃; 32℉ ~ 158℉

Maximum environmental temperature: 50℃ (122℉)

Maximum operating pressure: 10 bar (145 PSI)

Maximum suction pressure is limited by maximum operating

 

pressure

2-pole induction motor

Single-phase: 110-120/60Hz

Input thermal protector

Insulation class: F

Protection: IP55

Thank you for your purchase of a RainFlo Pump!

1) 

Applications

:

2) 

Operation Conditions:

3) 

Motor

:

Summary of Contents for MHP75A

Page 1: ...MHP75A MHP150A User Manual It is the installer s responsibility to read understand and comply with these instructions...

Page 2: ...ance Mainly applicable for pumping industrial fluids such as mineral water soft water pure water clean oil and circulation and boosting of other weak chemical industrial mediums Rainwater harvesting s...

Page 3: ...eliably grounded with a circuit breaker The power cord should be less than 15 feet and approved for the current delivered to this pump Ensure that you have made the correct electrical connections for...

Page 4: ...rmal protector for damage The pump does not pump properly The head is too high The water level is too low Intake isn t in water No water Leak in inlet or outlet hoses Make sure the head isn t too high...

Page 5: ...15 95 5 43 6 30 1 NPT 4 33 4 25 33 13 75 5 11 9 29 8 19 Inlet 5 11 MHP75A Inlet is 1 NFPT MHP150A Inlet is 1 5 NFPT 9 Dimensions 10 MHP Pump Curve...

Page 6: ...s with most pump controllers the system high pressure is based on the pump output The pump start pressure low pressure threshold and start trigger is adjustable through a screw on the back side of the...

Page 7: ...for automatic start after a failure Power supply LED POWER Pump switch on LED ON Safety system activation LED FAILURE Power supply voltage 1 115 125V Maximum current 16 A Max pump power 1100W 1 25 HP...

Page 8: ...assembled and installed by personnel qualified in accordance with local laws regulations and codes 18 1 Water Connection Fig 1 The PC115A must always be installed with the arrows pointing upward conne...

Page 9: ...nner systematically every thirty minutes for 24 hours If the failure still persists after all these attempts the system will remain in this condition until the problem has been resolved by manual inte...

Page 10: ...through the suction side the pressure is well below normal with constant fluctuations The safety system will engage and stop the pump the FAILURE LED will light up Check the seal and connections in t...

Page 11: ...34 32 30 28 26 44 42 40 38 36 24 22 20 18 16 14 12 10 8 6 4 2 0 GPM 30 50 40 20 10 0 H ft PC115A Friction Loss...

Page 12: ...MHP75A MHP150A Pump...