17
After the authorized staff completes the settings, he should readjust seal rings and
markings all over the appliance and replace the labels including information relating
to the used gas with the labels including information relating to the new adjusted gas.
After completing injector replacement, place the fire bars and burners and make sure
of fitting them properly.
WARNING:
The gas conversion must be performed by qualified service personnel.
Gas Type
and Pressure
Burner Type
Injector
LPG (BUTANE)
G 30
30 mbar
Big Wok
Small Wok
Rapid
Semi Rapid
A
uxiliary
0,95
0,85
0,85
0,65
0,50
NG (NATURAL)
G 20
20 mbar
Big Wok
Small Wok
Rapid
Semi Rapid
A
uxiliary
1,35
1,15
1,15
0,97
0,72
Table 1
ELECTRICAL CONNECTION
All electrical connections should be made only by licensed electric technician in accordance
with the applicable law and regulations. Connections must be in accordance with national
regulations.
Electrıc Connectıon Device Before
Which is positioned on the front bottom of the main power is supplied from the mains
power will meet the specified record label sure.
Grounded plug is mounted to oven energy supply cord.This must used with grounding-
line.Please make a qualified electirical grounding installation.
Connection of the product to the mains power can be made only by authorized and
licensed person and the product’s warranty commence only after right installation.
WARNING: This appliance must be earthed.
Power supply cable in;
Yellow / green, the grounding cable must be connected to the terminal.
Blue neutral wire connected to the terminal marked with the’’N’’.
Black, brown or red electrical cables installed must be connected to edge indicated by the’’L’’
.
(See Figure 7)
Summary of Contents for RBH-4634 BF
Page 1: ...BUILT IN HOB USER MANUEL...
Page 11: ...11 Connection type for 20 30 40 mm bench Point A Connection holes...
Page 12: ...12 Connection type of sealing ring...
Page 20: ...20...
Page 21: ...21...
Page 22: ...22...
Page 34: ...34 35 37 41 47 47 52 53 53 54 60 67 68 69...
Page 38: ...38...
Page 39: ...39...
Page 40: ...40 CO...
Page 41: ...41...
Page 42: ...42 2 3 100 C 30 1 min 30 mm...
Page 43: ...43 1 5 100 2 5 10 50 2 10 65 c 2 A C E 1...
Page 44: ...44 2...
Page 45: ...45 3 20 30 40 A...
Page 46: ...46...
Page 47: ...47 125...
Page 48: ...48 4 LPG 4 1 LPG 2 1 4 5 200 1 2 5...
Page 49: ...49 5 6...
Page 50: ...50 6 1 2 3 4 5 1...
Page 52: ...52 N L 7 7...
Page 53: ...53 wok wok 26 30 24 26 c 20 22 c 12 18 c...
Page 54: ...54 8 8...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58...
Page 59: ...59 1 2 3 4 WOK 5 WOK 7 8 9 10 WOK 11 WOK 13 14 15 16...
Page 60: ...60 9 9 10 10...
Page 61: ...61 3 4 3 4 1 1 3 5 15...
Page 62: ...62 15 1 wok wok wok wok wok wok WOK...
Page 63: ...63 0 90 Wok wok...
Page 64: ...64 0 2 0 1 2 3 2 10 15 11...
Page 65: ...65 11 3 145 150 200 3...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70 WEEE 2012 19 U...
Page 71: ......
Page 72: ......