background image

 

 

Level 1 PROGRAMMING 

STEP 1 : Set Current Time 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

1.

 

Press “ ” (MENU) for 3 
seconds to unlock screen.  

 

5.

 

Press “

” (SET/REGEN) 

once and the highlighted 
value flashes. 

6.

 

Now press “

” (UP) or “ ” 

(DOWN)  key  to  change  the 
hour values to current time.   

 

7.

 

Press 

” 

(SET/REGEN) 

again.  Hour  value  will  be 
accepted and minute value 
will start flashing.   

 

JAN/21/2015

JAN/21/2015

JAN/21/2015

JAN/21/2015    

05:27 PM

05:27 PM

05:27 PM

05:27 PM    

2.

 

The display will read “

Press 

MENU Key for 3 sec to 
unlock”

3.

 

After 3 seconds, the display 
will beep confirming unlock 

4.

 

Press “ ” (MENU) again and 
the hour value becomes 
highlighted 

PRESS MENU KEY 

PRESS MENU KEY 

PRESS MENU KEY 

PRESS MENU KEY     

3 SEC TO UNLOCK

3 SEC TO UNLOCK

3 SEC TO UNLOCK

3 SEC TO UNLOCK    

  

  

  

  

CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   05

05

05

05

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   05

05

05

05

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  

CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME

    

   

   

   

   00007777

    

: 27 PM

: 27 PM

: 27 PM

: 27 PM

    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   07 : 

07 : 

07 : 

07 : 

27

27

27

27

    PM

PM

PM

PM    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   07 : 

07 : 

07 : 

07 : 

45

45

45

45

    PM

PM

PM

PM    

8.

 

Now press “

” (UP) or “ ” 

(DOWN)  key  to  change  the 
minute  value  to  current 
time 

 

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   07 : 

07 : 

07 : 

07 : 45

45

45

45    

PM

PM

PM

PM

  

    

9.

 

Press 

” 

(SET/REGEN) 

again. Minute value will be 
accepted 

and 

AM/PM 

value will start flashing.   

 

10.

 

Now press “

” (UP) or       “ ” 

(DOWN) key to change the value 
to AM or PM  

 

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   

07

07

07

07

    : 45 AM

: 45 AM

: 45 AM

: 45 AM    

  

  

  

  CURRENT TIME

CURRENT TIME

CURRENT TIME

CURRENT TIME    

   

   

   

   07 : 

07 : 

07 : 

07 : 45

45

45

45    

AAAAMMMM

  

    

11.

 

Press  “

”  (SET/REGEN)  again  to 

accept.  Flashing  stops  &  hour 
value 

is 

highlighted 

again. 

PROCEED TO STEP 2

 

 

Summary of Contents for CBF1

Page 1: ...he phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EST www rainfresh ca TABLE OF CONTENTS System Specifications 2 How the CBF1 System Works 2 Safety Precautions 2 Cautions before In...

Page 2: ...ell pump flow rate must exceed the backwash flow rate 5 US GPM 19 LPM If your well pump does not deliver this flow rate do not install the unit as it will not work properly You may need to either chan...

Page 3: ...floor and drop it gently but firmly down favoring the side that needs to be adjusted to make the filter stand straight up again Make sure your chosen location is fairly level dry and protected from po...

Page 4: ...to install a water softener for soft water or a UV system for disinfecting the water these should be installed after the CBF1 filter see Fig 2 BEFORE YOU BEGIN INSTALLATION CONFIRM THE INLET AND OUTL...

Page 5: ...rain line more than 30 feet overhead increasing the line size to 3 4 will be required Please follow your local health dept Codes for where to run filter discharge water NEVER MAKE A DIRECT CONNECTION...

Page 6: ...NG WAIT PLEASE Do not touch any buttons at this time When the valve reaches the service position it will display the following information in sequence 1 Date Time 2 Regeneration Days Time interval bet...

Page 7: ...7 PM 27 PM 27 PM CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 05 05 05 05 27 PM 27 PM 27 PM 27 PM CURRENT TIME CURRENT TIME CURRENT TIME CURRENT TIME 0 0 0 07 7 7 7 27 PM 27 PM 27 PM 27 PM CURR...

Page 8: ...21 201 201 201 2012 2 2 2 CURRENT DATE CURRENT DATE CURRENT DATE CURRENT DATE AUG AUG AUG AUG 15 15 15 15 201 201 201 2012 2 2 2 16 Now press or key to change the value to current day of the month CUR...

Page 9: ...T Option 1 Option 2 Option 3 Comments System Language English Spanish French Set to French if desired Spanish not enabled Valve Operation Filter Softener Iron Filter Leave at default setting Backwash...

Page 10: ...this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency such as a leak you can isolate your filter system from the water supply using the bypass valve...

Page 11: ...an control valve inlet D Filter media in drain line 1 Incorrect or missing drain line flow control DLFC 1 Check and replace DLFC E Filter media in plumbing lines 1 You have reversed the inlet outlet o...

Page 12: ...ton pin 1 A06 05056023 End plug 1 A07 05056070 Quad ring 2 A08 05056024 End plug washer 1 A09 05056022 Piston retainer 1 A10 05056181 Piston electrical 1 A11 05056104 Muffler 1 A12 05056021 Spacer 4 A...

Page 13: ...A27 07060007 Valve bottom connector 1 A28 26010103 O ring 25x3 55 1 A29 05056063 O ring 78 74x5 33 1 A30 05056086 Screw M5x30 Hexagon with washer 2 A31 05056029 Injector cover 1 A32 05056072 O ring 2...

Page 14: ...to the Warrantor at the owner s expense and in accordance with shipping instructions received from the Warrantor This warranty does NOT cover and is intended to exclude any liability on the part of En...

Reviews: