1
INSTALLATION AND OPERATING INSTRUCTIONS FOR
COMBI-OVEN WATER FILTRATION SYSTEM
MODEL CORO_00N
INSTALLATION CAUTIONS
Installation must conform to all local and state plumbing codes and regulations.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
Do not exceed Maximum Pressure = 100 psi (690 kPa). If water pressure surges, or will at any time
exceed the 100 psi maximum, a pressure regulator must be installed before the filter (recommended
regulator setting is 75 psi or less) along with a water hammer arrestor to prevent potentially
damaging shocks caused by water hammer.
Connect system to cold water supply only. Water temperature should not exceed 100⁰F/28⁰C. Do
not subject the system to freezing temperatures
Do not install system in direct sunlight or where system is exposed to harsh chemicals or may be
subjected to being struck by moving equipment, carts, mops or any other item that may cause
damage.
ALLOW a minimum of 5” under the unit to allow for filter replacement.
Do not run any tubing under or touching the oven
Ensure that any part of the tubing does not come into contact with any heat source
SYSTEM SPECIFICATIONS
Maximum Pressure
:
100 psi/8.6 bar
Maximum Temperature
:
100°F (38⁰C), Min.: 35⁰F (2⁰C)
Connections
:
Inlet - 3/8” tube ; Outlet, Drain & Tank – ¼” tube
Storage tank capacity
:
3.2 US gal (max) at 60 psi
FEED WATER QUALITY
Water hardness
:
Max 7 GPG
Iron
:
< 0.3 PPM
Manganese
:
< 0.05 PPM
Turbidity
:
1 NTU max
Oil, gases & bacteria
:
None
SYSTEM DIMENSIONS
Model
Unit Width (Inch)
Unit Height (Inch)
Unit Depth (Inch)
CORO_00N
16.5”
22.5”
6”
OPENING THE PACKAGE
The CORO system includes the following:
The main wall-mount unit
Storage tank
6 feet of 3/8” poly tubing
18 feet of ¼” poly tubing
Wall mounting washer strip and mounting screws