background image

2.  Turn sump 1/8th turn to left and lower to remove and at same time remove ceramic cartridge by twisting and gently pulling  
 

downwards. Do not remove cartridge by unscrewing from adaptor (2560). Transfer cartridge and sump to sink and dump  

 water.
3.  To clean ceramic, 

(Note: Please wear rubber gloves)

 hold cartridge in palm of hand with nozzle up and gently scrub entire  

 

surface with abrasive screen cleaner (811-0) provided under running water. Do not allow water to enter nozzle opening. 

 

DO NOT USE SOAP OR DETERGENTS.

 Scrubbing removes trapped particulates along with part of the ceramic.

4.  Insert ceramic cartridge with adaptor (2560) back into head boss. Replace sump and turn 1/8 turn to right fully to stop
 (lock 

position). 

Note:

 Bottom of sump has guides to contain 1M cartridge. Sump will not lock unless bottom of cartridge is  

 between 

guides. 

5.  Open saddle valve to start water flow then open faucet until all trapped air has escaped. If air remains in ceramic
 

housing, turn off faucet and press top vent button until water level rises past sealing point on sump.

Replacing CF2 Cartridge - Every 4 months

1.  Close saddle valve by turning clockwise and open faucet to relieve pressure in filter. Press vent buttons on top of both  
 heads.
2.  Remove right sump and lower and at same time remove carbon cartridge by twisting and gently pulling downwards.   
 

Transfer cartridge and sump to sink and dump water.

3.  Insert new CF2 cartridge onto head boss and replace and lock sump. Open saddle valve to start water flow.
4.  Turn on faucet until trapped air has escaped. If air remains in housing, turn off faucet and press top vent button until water  
 

level rises past sealing point on sump. Note: Some fines from carbon cartridge may be flushed onto ceramic cartridge.  

 

These are harmless and are removed with next cleaning.

Replacing 1M Ceramic Cartridge - Every 12 months

1.  Follow steps 1 & 2 above to remove sump and ceramic cartridge only.
2. 

REMOVE CARTRIDGE ADAPTOR (2560) FROM OLD CARTRIDGE.

 Thread adaptor onto new cartridge. 

Take care not to  

 cross 

thread.

 Wipe any accumulated dirt from head boss before inserting new cartridge.

3.  Replace cartridge by twisting and pushing up gently on head boss. Replace and lock sump. Open saddle valve to start  
 water 

flow.

4.  Turn on faucet until trapped air and carbon fines are flushed. If air remains in ceramic housing, turn off faucet and press top  
 

vent button until water level rises past sealing point on sump.

MAINTENANCE / CAUTIONS
Caution:

 If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove cartridges from 

sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days.

Note:

 Lubricate Head O-rings (2502) at least once a year and when draining for winter. Use food grade silicone grease (i.e. 

Dow 111 compound) or any other non petroleum lubricant. Water conditions can be hard on rubber seals. Head O-ring (2502) 
replacement at least every two years is recommended to minimize wear and tear and prevent leakage.

Caution:

 Due to a limited product service life and to prevent costly repairs or possible water damage, we strongly recommend 

that sumps (#520) be replaced every 5 years. If sumps of your filter unit have been used for more than this period, replace 
immediately. Date the bottom of any new sump to indicate next replacement date.

Do Not 

clean housing with organic solvents such as those found in sprays for cleaning products or insecticides as these may 

cause cracking or crazing and lead to failure and leakage. 

Protect filter

 from direct sunlight. Not intended for outdoor use. 

Note:

  For cold water use only.

TROUBLESHOOTING GUIDE

Problem

 

Solution

1.  Sump is difficult to remove 

-  Unit may still be under pressure. Close saddle valve and

  

 

  open faucet to relieve pressure.

 

 

-  Head O-ring may be stuck. To break the seal, push up on

     

  the sump before turning to unlock.

2.   Leak at Head O-ring 

-  O-ring may be dry or cracked due to age. Remove sump,

     

  cartridge and O-ring. Lubricate O-ring with food grade

     

  Silicone (i.e. Dow 111 Compound) or non petroleum

     

  lubricant and reinstall.  If seal still leaks, replace it.

3.   Leak at Vent Button 

-  Vent O-ring is not seating properly or is dry or cracked.

     

  Press vent button several times to re-seat vent o-ring. 

     

  If O-ring still leaking, contact Envirogard for vent O-ring

     

  replacement kit.

4.   Flow rate is very slow after installation of unit 

-  Call Envirogard to review installation procedure.

OPERATING SPECIFICATIONS
MAXIMUM PRESSURE

- 100 psi / 690 kPa. 

MAXIMUM TEMPERATURE

 - 100°F / 38°C.

Cartridge Life 

 

- CF2 - 375 gal / 1491 L or 4 months                            

 

- 1M - 1 year

Rated Service Flow

 - 0.75 gpm / 2.8 Lpm

3

Summary of Contents for UCS2

Page 1: ...arefully before proceeding and keep instructions for future use System and installation shall comply with applicable state and local regulations This unit comes complete with cartridges faucet assembl...

Page 2: ...artridge 1M Push open end blue end cap of CF2 over boss of white head inlet side To replace sump align the sump grooves with inlet head 2501 lugs and push straight up onto the head Turn the sump 1 8 t...

Page 3: ...mp Open saddle valve to start water flow 4 Turn on faucet until trapped air and carbon fines are flushed If air remains in ceramic housing turn off faucet and press top vent button until water level r...

Page 4: ...verification for reduction of bacteria cyst and particulates performed by independent laboratory Part Name Part No Qty Activated Carbon Cartridge CF2 1 Ceramic Cartridge 1M 1 Cartridge O Ring 517 1 Su...

Page 5: ...d installer le filtre Le syst me et son installation doivent tre conformes aux r glements locaux en vigueur Ce syst me comprend les cartouches le robinet et toutes les fixations n cessaires pour effe...

Page 6: ...l autre r ceptacle de la t te en l en fon ant et en la tournant en m me temps Ins rez le carter dans la t te et tournez le de 1 8 de tour vers la droite pour le bloquer en place Remarque le fond du ca...

Page 7: ...urs de l air dans le carter fermez le robinet et appuyez sur le bouton de purge jusqu ce que le niveau d eau d passe le joint d tanch it dans le carter Entretien mises en garde 1 Mise en garde si votr...

Page 8: ...agasin Appelez nous Assistance clients 1 800 667 8072 Toronto et la r gion 905 884 9388 Site Web www rainfresh ca ENVIROGARD PRODUCTS LIMITED 446 Major Mackenzie Dr E Unit 6 Richmond Hill ON L4C 1J2 C...

Reviews: