Step 4: Install Supply Fitting 

Use the 2557 supply fitting if the water supply pipe under the sink attaches to a 3/8” 
flex pipe from the kitchen faucet. If your piping is different or if you do not have a 
shut-off valve under the sink, you can order Rainfresh 

CK538

 or 

CKT38

 valves 

(depending upon your piping) directly from 

www.rainfreshstore.ca

 

 

IMPORTANT:

 Before you install supply fitting, confirm the cold water pipe by running 

hot water through your kitchen faucet and touching both pipes.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Step 5 : Start up 

 

Remove wrapping from carbon cartridge (CF2) and carefully place it 
into the sump (on the side of the inlet fitting – see page 8) 

with blue 

gasket facing up

. Align the sump under the filter head and pull the 

cartridge up with one hand and push blue gasket over boss of white 
head (see fig 9). Pull sump up and rotate to right 1/8 turn to align the 
sump grooves with lugs on the head (2501) to lock position (Fig 10) 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

Now remove wrapping on the 1M ceramic cartridge and carefully place it into the sump with open end facing up. 
Align the sump under the filter head and pull the cartridge up with one hand and push the cartridge seal into the 
boss of white head (

outlet side

). Pull sump and lock into position (Fig 9). 

Note: 

Bottom of sump has alignment 

guides to contain 1M cartridge. Sump will not lock unless bottom of cartridge is between guides

 

Turn faucet handle on to ON position. Turn supply valve handle to open and start water flow.  

 

Close faucet and check all connections for leaks. Carefully retighten any leaking fittings. Check the unit a few times over the 
next day or two for slow leaks shortly after installation. 

HEAD LUG 

SUMP  
GROOVE 

FIG 9 

WRONG POSITION 

Index marks not aligned

 

 

Sump grooves & head 

lugs not aligned. Sump 

has not been turned fully 

to LOCK position.  

 
 
 

CORRECT POSITION

 

Index marks aligned 

 

Sump grooves past the head 

lug. Sump has been turned 

fully to LOCK position.  

 

LOCK 

FIG 10 

Now turn off the cold 
water supply valve to 
the kitchen faucet. 

Using a wrench, 
unscrew the faucet 
tube from the supply 
valve. 

Thread in the 2557 
supply adapter & then 
attach the faucet tube 
to it. 

Push the open end of the filter 
INLET tubing into the supply 
adapter until it cannot go in 
any further. 

TO 

FILTER 

INLET 

CKT38 

3/8”x3/8”x3/8” 

CK538 

½”x½”x3/8” 

Summary of Contents for UCS2

Page 1: ...o CSA Standard B483 1 to NSF ANSI Standard 53 for reduction of Cyst e g Cryptosporidium Giardia and lindane to NSF ANSI Standard 42 for reduction of chlorine taste odour and to NSF ANSI 372 The standa...

Page 2: ...regulator setting is 75 psi 5 1 bar 517 kPa or less o Note Do not install in multi storey buildings over 4 storeys o Do not subject to freezing temperatures with water inside the unit If your unit wil...

Page 3: ...t should not be installed more than fifteen feet away from the faucet Call Rainfresh if you have questions Remove each sump 520 by turning it 1 8 turn left then pulling away from head 2501 Fig 3 Remov...

Page 4: ...NIMUM OF 18 INCHES CLEARANCE from the top edge of the bracket to the cabinet floor THE HIGHER AND CLOSER TO THE FRONT YOU MOUNT THE UNIT THE BETTER FOR REGULAR MAINTENANCE 2 Partially screw the 2 moun...

Page 5: ...g up Align the sump under the filter head and pull the cartridge up with one hand and push the cartridge seal into the boss of white head outlet side Pull sump and lock into position Fig 9 Note Bottom...

Page 6: ...odour VC1 Chemicals VOC THM etc chlorine taste and odour LR1 Lead chemicals VOC THM etc chlorine taste and odour Ceramic filter 1M Bacteria parasites E coli etc 1 year Head seals 2502 1 year Sump 520...

Page 7: ...un some water through the system until you smell the bleach coming out of the faucet Turn off faucet immediately and let bleach stay in the system Turn OFF the supply valve 5 After 4 6 hours open sump...

Page 8: ...y shall consist of repair replacement or credit at its option of any part found by the Company inspection to be defective provided that the product has not been misused abused altered or damaged as de...

Page 9: ...infresh Nous nous engageons vous donner enti re satisfaction Si vous avez des questions lors de l installation de l utilisation ou de la maintenance de votre nouveau syst me ne retournez pas au magasi...

Page 10: ...ts de plus de quatre tages o Ne pas exposer des temp ratures inf rieures 0 C lorsqu il y a de l eau l int rieur du syst me Si vous n utilisez pas votre syst me en hiver ou s il est expos des temp ratu...

Page 11: ...ll plus de 4 5 m 15 pi du robinet En cas de questions appelez Rainfresh Enlevez les carters 520 des t tes 2501 Fig 3 en les tournant de 1 8 de tour vers la gauche tout en tirant dessus Retirez la cart...

Page 12: ...gabarit pour marquer l emplacement des trous Fig 5 Remarque LAISSEZ AU MOINS 18 POUCES de d gagement sous du bord sup rieur du support LE PLUS LEV ET PLUS PR S QUE VOUS MONTEZ L UNIT L MEILLEUR IL SER...

Page 13: ...vec l extr mit ouverte orient e vers le haut Alignez le carter sous la t te de filtre tirez la cartouche vers le haut avec une main et poussez le joint de la cartouche dans la t te blanche c t sortie...

Page 14: ...ou f ler les carters et causer une fuite l ment MOD LE FONCTION Fr quence de remplacement Trouvable Pr filtre CF2 Chlore go t et odeur Quatre six mois Chez les grands d taillants ou dans les magasins...

Page 15: ...CONGELER 3 Ajouter de tasse de javellisant inodore dans le premier carter puis fixez nouveau les deux carters au syst me 4 Ouvrez la valve d alimentation et laissez couler de l eau travers le syst me...

Page 16: ...d achat initial Aux termes de la pr sente garantie la soci t s engage r parer ou remplacer sa discr tion toute pi ce qu elle juge d fectueuse pourvu qu elle ne d termine pas que le filtre a t modifi o...

Reviews: