Flushing and conditioning

: Allow water to flow for 10 minutes to flush unit then close faucet and allow unit to sit overnight 

to condition. In the morning flush unit briefly before beginning service. 

YOUR UNIT IS NOW IN OPERATION. 

Note:

 

In some cases with low water pressure, the OUTLET sump may only partially fill due to an air block. If this happens, 

turn off faucet and press top vent button until water level rises past the sealing point on sump. 

Note:

 It is normal for the 

water to initially have some carbon fines (tiny black particles). It is also normal for the water to appear cloudy for 
the first few 

days and is safe to drink. The cloudiness is caused by small air bubbles that get displaced from the filters. If 

you leave the water standing for a few seconds, the cloudiness will disappear. Running the unit for extended periods of 
time will 

NOT

 help.  

 

(E) MAINTENANCE  

 

Caution:

 

If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove 

cartridges from sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days.  

 

Note:

 

Lubricate Head O-rings (2502) after every cartridge change/cleaning and when draining for winter. Use food 

grade silicone grease (i.e. Dow 111 compound) or any other non-petroleum lubricant. 

 

Note:

 Do Not 

clean housing with organic solvents such as those found in sprays for cleaning products or 

insecticides as these may cause cracking or crazing and lead to failure and leakage. 

 

Item 

PART # 

FUNCTION 

Replacement 

Frequency 

Where available 

Pre-filter 

CF2 

Chlorine, taste & odour 

4-6 months 

Major retailers or home 

improvement stores 

Optional  pre-filter 

CA1 

Chloramine, chlorine, taste and odour 

VC1 

Chemicals (VOC, THM etc.), chlorine, 

taste and odour 

LR1 

Lead, chemicals (VOC, THM etc.), 

chlorine, taste and odour 

Ceramic filter 

1M 

Bacteria, parasites, E. coli etc. 

1 year 

Head seals 

2502 

 

1 year 

Sump** 

520 

 

5 years 

Call Rainfresh or order 

online at 

www.rainfreshstore.ca 

Vent pin assembly 

2505 

 

5 years 

Other parts 

 

 

 

*

Note:

 

Cartridge life is directly dependant on water conditions and volume of water filtered. Excessive sediment may cause 

more frequent replacement. Contaminants reduced by these filters/cartridges are not necessarily in your water. 

** 

Caution:

 

It is highly recommended to replace sumps at least once every 5 years to prevent costly repairs or 

possible water damage. Record date of installation of new sump at the bottom.

 

 

 

(a)

 

Cleaning or replacing 1M Ceramic Cartridge 

This cartridge is cleanable and reusable. The flow rate will gradually slow during use as 
contaminants build up on the ceramic surface. The flow is restored by scrubbing the surface of 
the cartridge as required using the abrasive cleaning pad (811-0) enclosed.  

 

1)

 

Close supply valve and open faucet to release pressure in filter or press vent buttons on 
top of either heads. 

2)

 

Turn sump 1/8th turn to left and lower to remove and at same 
time remove ceramic cartridge by twisting and gently pulling 
downwards. Do not remove cartridge by unscrewing from adaptor 
(2560). Transfer cartridge and sump to sink and dump water.  

3)

 

To clean ceramic, 

(

Note:

 Please wear rubber gloves) 

hold cartridge 

in palm of hand with nozzle up and gently scrub entire surface with 
abrasive screen cleaner (811-0) provided under running water. 

Do not allow water to enter nozzle opening. DO 

NOT USE SOAP OR DETERGENTS. 

Scrubbing removes trapped particulates along with part of the ceramic.  

4)

 

Replace ceramic cartridge if cartridge gauge (703-4) can be passed over the width of the ceramic 

5)

 

Refer to Step 5: Start Up on Page 5 

703-4 

703-4 

Summary of Contents for UCS2

Page 1: ...o CSA Standard B483 1 to NSF ANSI Standard 53 for reduction of Cyst e g Cryptosporidium Giardia and lindane to NSF ANSI Standard 42 for reduction of chlorine taste odour and to NSF ANSI 372 The standa...

Page 2: ...regulator setting is 75 psi 5 1 bar 517 kPa or less o Note Do not install in multi storey buildings over 4 storeys o Do not subject to freezing temperatures with water inside the unit If your unit wil...

Page 3: ...t should not be installed more than fifteen feet away from the faucet Call Rainfresh if you have questions Remove each sump 520 by turning it 1 8 turn left then pulling away from head 2501 Fig 3 Remov...

Page 4: ...NIMUM OF 18 INCHES CLEARANCE from the top edge of the bracket to the cabinet floor THE HIGHER AND CLOSER TO THE FRONT YOU MOUNT THE UNIT THE BETTER FOR REGULAR MAINTENANCE 2 Partially screw the 2 moun...

Page 5: ...g up Align the sump under the filter head and pull the cartridge up with one hand and push the cartridge seal into the boss of white head outlet side Pull sump and lock into position Fig 9 Note Bottom...

Page 6: ...odour VC1 Chemicals VOC THM etc chlorine taste and odour LR1 Lead chemicals VOC THM etc chlorine taste and odour Ceramic filter 1M Bacteria parasites E coli etc 1 year Head seals 2502 1 year Sump 520...

Page 7: ...un some water through the system until you smell the bleach coming out of the faucet Turn off faucet immediately and let bleach stay in the system Turn OFF the supply valve 5 After 4 6 hours open sump...

Page 8: ...y shall consist of repair replacement or credit at its option of any part found by the Company inspection to be defective provided that the product has not been misused abused altered or damaged as de...

Page 9: ...infresh Nous nous engageons vous donner enti re satisfaction Si vous avez des questions lors de l installation de l utilisation ou de la maintenance de votre nouveau syst me ne retournez pas au magasi...

Page 10: ...ts de plus de quatre tages o Ne pas exposer des temp ratures inf rieures 0 C lorsqu il y a de l eau l int rieur du syst me Si vous n utilisez pas votre syst me en hiver ou s il est expos des temp ratu...

Page 11: ...ll plus de 4 5 m 15 pi du robinet En cas de questions appelez Rainfresh Enlevez les carters 520 des t tes 2501 Fig 3 en les tournant de 1 8 de tour vers la gauche tout en tirant dessus Retirez la cart...

Page 12: ...gabarit pour marquer l emplacement des trous Fig 5 Remarque LAISSEZ AU MOINS 18 POUCES de d gagement sous du bord sup rieur du support LE PLUS LEV ET PLUS PR S QUE VOUS MONTEZ L UNIT L MEILLEUR IL SER...

Page 13: ...vec l extr mit ouverte orient e vers le haut Alignez le carter sous la t te de filtre tirez la cartouche vers le haut avec une main et poussez le joint de la cartouche dans la t te blanche c t sortie...

Page 14: ...ou f ler les carters et causer une fuite l ment MOD LE FONCTION Fr quence de remplacement Trouvable Pr filtre CF2 Chlore go t et odeur Quatre six mois Chez les grands d taillants ou dans les magasins...

Page 15: ...CONGELER 3 Ajouter de tasse de javellisant inodore dans le premier carter puis fixez nouveau les deux carters au syst me 4 Ouvrez la valve d alimentation et laissez couler de l eau travers le syst me...

Page 16: ...d achat initial Aux termes de la pr sente garantie la soci t s engage r parer ou remplacer sa discr tion toute pi ce qu elle juge d fectueuse pourvu qu elle ne d termine pas que le filtre a t modifi o...

Reviews: