background image

 

(D) INSTALLATION

 

 

Installation shall comply with applicable state and local regulations 

 

The ceramic filter cartridge in this unit is FRAGILE and should be treated like chinaware

.  

 

Protect filter 

from direct sunlight. Not intended for outdoor use.  

 

If your undersink pipe is PEX, the supply valve included should not be used. 

You can order the PEX supply valve 

(model CK538) online at www.rainfreshstore.ca. You will receive this in 2-3 business days. You can also call 
Rainfresh at 1800 667 8072 and order this over the phone. 

 

TOOLS REQUIRED: 

 Drill, ½” drill bit, Philips & flat-head screwdrivers, adjustable wrench, marker or pencil, a sharp knife 

and measuring tape. 

 

Unpacking the unit

 

The following items are included in the box 

 

Main filter unit 

 

One pre-filter (CF2) and one post filter (LR1) 

 

One ceramic cartridge (1M), cartridge gauge & scrub pad 

 

6 feet of 3/8” OD tubing 

 

Self-piercing supply valve for copper pipes 

 

Chrome faucet & faucet adapter fittings 

Remove each sump (520) by turning it 1/8 turn left, then pulling away from head (2501). Remove pre-filter & post filter 
cartridges (CF2 & LR1) by gently twisting and pulling away from head boss. The ceramic cartridge (1M) is packed 
separately. Set both cartridges aside in a safe place until final assembly. 
 
The  following  instructions are  for  installing  the  UCS3  system under  the  sink.  It  can  also be  installed on any other  wall 
mounted remote location (such as basement or crawl space) from where tubing can be run to the faucet. The unit should 
not  be  installed  more  than  fifteen  feet  away  from  the 
faucet. Call Rainfresh if you have questions. 
  

Step 1: Mounting the Faucet 

Faucet may be installed in hole in sink if available or in 
counter top. Note: The faucet may also be installed in the 
sink sprayer hole if available. 

1.

 

Position faucet on counter top beside sink in 
desired position. Ensure that swivel spout will 
extend over sink and that there is room under the 
counter for faucet shank and to tighten nuts. 

2.

 

Mark the location and drill a ½” hole (fig 2). Protect 
your counter top by applying a layer of masking 
tape and use a sharp drill.  

3.

 

Insert faucet shank through escutcheon plate (1040-9) and 
escutcheon washer (1040-10), and then through counter top 
(See Fig. 3). Install plastic locating washer (1040-12), lock 
washer (1040-13) and locking nut (1040-14). Tighten locking nut 
securely while someone holds the faucet body so it does not 
turn. Place adaptor washer (1040-16) inside 3/8” adapter (1040-
15) and tighten adaptor securely on to the faucet shank with a wrench. 

Note

: Do not use any thread sealant or 

tape on the faucet shank. 

 

Step 2: Mounting the Unit

 

1.

 

Locate best position for mounting unit undersink near faucet. Mark 
mounting bracket screw locations using mounting bracket (2570) as a 
template (fig 4). 

NOTE: 

LEAVE 

MINIMUM OF 5 INCHES 

CLEARANCE 

BELOW SUMPS TO ALLOW REMOVAL OF CARTRIDGES FOR CLEANING 

Summary of Contents for UCS3

Page 1: ...for reduction of Lead VOC Cyst e g Cryptosporidium Giardia and lindane to NSF ANSI Standard 42 for reduction of chlorine taste odour and to NSF ANSI 372 The standards referenced above evaluate product...

Page 2: ...be installed before the filter to prevent potentially damaging shocks caused by high pressure Recommended regulator setting is 75 psi 5 1 bar 517 kPa or less Not intended for installation in multi st...

Page 3: ...t can also be installed on any other wall mounted remote location such as basement or crawl space from where tubing can be run to the faucet The unit should not be installed more than fifteen feet awa...

Page 4: ...to 1 diameter If your piping is PEX or any other softer material DO NOT USE this supply valve as it can cause leaks For PEX you can purchase appropriate fittings at the same store where you purchased...

Page 5: ...ly after installation Flushing and conditioning Allow water to flow for 10 minutes to flush unit then close faucet and allow unit to sit overnight to condition In the morning flush unit briefly before...

Page 6: ...and open faucet to relieve pressure in filter Press vent buttons on top of both heads 2 Remove right sump and lower and at same time remove carbon cartridge by twisting and gently pulling downwards Tr...

Page 7: ...p of fresh unscented bleach to the first sump reattach all sumps to the unit 4 Open the supply valve and run some water through the system until you smell the bleach coming out of the faucet Turn off...

Page 8: ...onsist of repair replacement or credit at its option of any part found by the Company inspection to be defective provided that the product has not been misused abused altered or damaged as determined...

Page 9: ...s 10 D Installation 11 a Installation du robinet 11 b Montage de l unit 11 c Raccordement du robinet 12 d Installation de la soupape trier 12 e Commencez 13 E Nettoyage et remplacement des cartouches...

Page 10: ...ression trop lev e Le r glage recommand du r gulateur est de 75 psi 5 1 bar 517 kPa ou moins Syst me de filtration non destin tre install dans des b timents de plus de quatre tages Ne pas exposer des...

Page 11: ...galement tre install tout autre endroit distant support mural comme un sous sol ou un vide sanitaire d o les tuyaux peuvent tre achemin s jusqu au robinet L appareil ne doit pas tre install plus de 4...

Page 12: ...tif ou vous pouvez commander le kit de la valve d alimentation mod le CK538 sur le site www rainfreshstore com IMPORTANT Avant de proc der l installation de la valve d alimentation confirmez la condui...

Page 13: ...a pas de fuite lente Rin age et conditionnement Laissez couler l eau pendant 10 minutes pour rincer le syst me puis fermer le robinet toute la nuit pour conditionner le syst me Le lendemain matin lai...

Page 14: ...joint d tanch it dans le carter Remplacement de le cartouches CF2 et LR1 Tous les 6 mois 1 Fermez la soupape triers et ouvrez le robinet de fa on d pressuriser le filtre Pressez les boutons de purge...

Page 15: ...nt la valve d alimentation et ouvrez le robinet pour vacuer la pression 2 Retirer les cartouches de leurs carters respectifs et mettez les de c t dans votre r frig rateur NE PAS CONGELER 3 Ajouter de...

Page 16: ...achat initial Aux termes de la pr sente garantie la soci t s engage r parer ou remplacer sa discr tion toute pi ce qu elle juge d fectueuse pourvu qu elle ne d termine pas que le filtre a t modifi ou...

Reviews: