(D) INSTALLATION
Installation shall comply with applicable state and local regulations
The ceramic filter cartridge in this unit is FRAGILE and should be treated like chinaware
.
Protect filter
from direct sunlight. Not intended for outdoor use.
If your undersink pipe is PEX, the supply valve included should not be used.
You can order the PEX supply valve
(model CK538) online at www.rainfreshstore.ca. You will receive this in 2-3 business days. You can also call
Rainfresh at 1800 667 8072 and order this over the phone.
TOOLS REQUIRED:
Drill, ½” drill bit, Philips & flat-head screwdrivers, adjustable wrench, marker or pencil, a sharp knife
and measuring tape.
Unpacking the unit
The following items are included in the box
Main filter unit
One pre-filter (CF2) and one post filter (LR1)
One ceramic cartridge (1M), cartridge gauge & scrub pad
6 feet of 3/8” OD tubing
Self-piercing supply valve for copper pipes
Chrome faucet & faucet adapter fittings
Remove each sump (520) by turning it 1/8 turn left, then pulling away from head (2501). Remove pre-filter & post filter
cartridges (CF2 & LR1) by gently twisting and pulling away from head boss. The ceramic cartridge (1M) is packed
separately. Set both cartridges aside in a safe place until final assembly.
The following instructions are for installing the UCS3 system under the sink. It can also be installed on any other wall
mounted remote location (such as basement or crawl space) from where tubing can be run to the faucet. The unit should
not be installed more than fifteen feet away from the
faucet. Call Rainfresh if you have questions.
Step 1: Mounting the Faucet
Faucet may be installed in hole in sink if available or in
counter top. Note: The faucet may also be installed in the
sink sprayer hole if available.
1.
Position faucet on counter top beside sink in
desired position. Ensure that swivel spout will
extend over sink and that there is room under the
counter for faucet shank and to tighten nuts.
2.
Mark the location and drill a ½” hole (fig 2). Protect
your counter top by applying a layer of masking
tape and use a sharp drill.
3.
Insert faucet shank through escutcheon plate (1040-9) and
escutcheon washer (1040-10), and then through counter top
(See Fig. 3). Install plastic locating washer (1040-12), lock
washer (1040-13) and locking nut (1040-14). Tighten locking nut
securely while someone holds the faucet body so it does not
turn. Place adaptor washer (1040-16) inside 3/8” adapter (1040-
15) and tighten adaptor securely on to the faucet shank with a wrench.
Note
: Do not use any thread sealant or
tape on the faucet shank.
Step 2: Mounting the Unit
1.
Locate best position for mounting unit undersink near faucet. Mark
mounting bracket screw locations using mounting bracket (2570) as a
template (fig 4).
NOTE:
LEAVE
MINIMUM OF 5 INCHES
CLEARANCE
BELOW SUMPS TO ALLOW REMOVAL OF CARTRIDGES FOR CLEANING